Datasheets.org.uk - 100 Million Datasheets from 7500 Manufacturers. |
TeSys contactors Model Type contactor LC1LC1LC1D09.D18
Top Searches for this datasheetVDE 0660 BS 5424 - VDE 0660 BS 5424 timer contactor - timer contactor tesys d contactors - tesys d contactors tesys* - tesys* schneider LC1-D80 - schneider LC1-D80 schneider LC1-D09 - schneider LC1-D09 LP1-D80 - LP1-D80 LC1-D80* - LC1-D80* LC1D40 OVERLOAD RELAY - LC1D40 OVERLOAD RELAY LC1-D40 DIMENSIONS - LC1-D40 DIMENSIONS LC1-D40* - LC1-D40* LC1D40 - LC1D40 LC1-D150* - LC1-D150* LC1-D115* - LC1-D115* LC1-D09 diagram - LC1-D09 diagram LC1-D09 coil voltage - LC1-D09 coil voltage LC1-D09 10 - LC1-D09 10 LC1-D09* - LC1-D09* lc1d* - lc1d* LC1 Schneider d65 - LC1 Schneider d65 LC1 Schneider - LC1 Schneider LC1 DT40 - LC1 DT40 LC1 D09 10 - LC1 D09 10 LC1 D09 - LC1 D09 LC1 D - LC1 D LC1 contactor - LC1 contactor LAD-4RC* - LAD-4RC* la6 dk20 - la6 dk20 la6 dk10 - la6 dk10 Characteristics TeSys contactors Model Type contactor LC1LC1LC1D09.D18 D25.D38 DT20 DT25 DT32.DT60 LC1D50.D95 LC1-D115 LC1-D150 Environment Rated insulation voltage (Ui) Conforming 60947-4-1, overvoltage category III, degree pollution: Conforming Rated impulse withstand voltage (Uimp) Conforming standards Conforming 60947 1000 947-1, 947-4-1, 63-110, 0660, 5424, 1038, 60947-1, 60947-4-1. DNV, PTB, RINA pending Complies with SNCF, Sichere Trennung recommendations Conforming 0106 parts (project 2/89) Conforming 0106 Power connection Coil connection Protection against direct finger contact Protection against direct finger contact (except LC1-D40.D80) "TH" 60.+ 40.+ operation 3000 possible, relation normal vertical mounting plane Product certifications Separation insulation Degree protection (front face only) Protective treatment Ambient temperature around device Conforming Storage Operation Permissible Maximum operating altitude Operating position Flame resistance Without derating Without derating Conforming Conforming 695-2-1 Shock resistance sine wave 11ms Contactor open Contactor closed Vibration resistance 5.300 Contactor open Contactor closed Protection ensured connection cross-sections shown next page connection cable. least favourable direction, without change contact state (coil supplied Ue). Selection: pages 1/35 2/32 References: pages Dimensions: pages 2/44 2/47 Schemes: pages 2/48 2/49 Schneider Electric Characteristics TeSys contactors Model Connections power control circuits Type contactor LC1- DT20 (3P) DT25 (4P) DT32.DT60 D115 D150 Power circuit connections Connection cable Tightening Flexible cable conductor without cable conductors Flexible cable with cable conductor conductors Screw clamps 1.2.5 DT25) DT25) 1.5.6 1.5.10 2.5.10 1.5.6 1.5.6 2.5.10 1.10 1.5.6 2-input connector 2.5.16 2.5.16 2.5.10 2.5.10 2.5.16 2.5.16 (10: DT32.DT60) Screw clamps 2.5.25 2.5.16 2.5.25 2.5.10 2.5.25 2.5.16 1-input connector 2-input connector 2.5.25 4.50 2.5.16 4.25 2.5.25 4.50 2.5.10 4.16 2.5.25 4.50 2.5.16 4.25 10.120 10.120 10.50 10.120 10.120 10.50 10.120 10.120 10.50 Solid cable conductor without cable conductors Screwdriver sided Tightening torque Connection spring terminals conductor Flexible cable without cable conductors Connection bars lugs cross-section external screw Screwdriver Phillips head flat screwdriver Phillips head flat screwdriver 1.5.6 1.5.6 1.5.10 1.5.6 1.5.6 2.5.10 M3.5 M3.5 hexagonal headed screw Tightening torque Control circuit connections Connection cable (tightening screw clamps) Flexible cable conductor without cable conductors Flexible cable with cable conductor conductors 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 1.2.5 Solid cable conductor without cable conductors Screwdriver Tightening torque Connection spring terminals Flexible cable conductor without cable conductors Connection bars lugs external screw Screwdriver Tightening torque Phillips head flat screwdriver Phillips head flat screwdriver M3.5 M3.5 M3.5 M3.5 Spade connector cable lug, connection cable above. Selection: pages 1/35 Schneider Electric References: pages Dimensions: pages 2/44 2/47 Schemes: pages 2/48 2/49 2/33 Characteristics TeSys contactors Model Type contactor LC1- DT20 DT25 DT32 DT40 Pole characteristics Rated operational current (Ie) Rated operational voltage (Ue) Frequency limits Conventional thermal current (Ith) Rated making capacity (440 Rated breaking capacity (440 Permissible short-time rating current flowing preceding minutes AC-3, AC-1, operating current Conforming Conforming Without thermal overload relay, fuse With thermal overload relay Average impedance pole Power dissipation pole above operating currents AC-3 AC-1 type type 25.400 25.400 25.400 25.400 Protection fuse against short-circuits pages 2/52 2/53, fuse ratings corresponding associated thermal overload relay 0.20 1.56 0.36 1.56 1.25 a.c. control circuit characteristics Rated control circuit voltage (Uc) Control voltage limits coils 50/60 coils 50/60 12.690 Operational Drop-out Operational Drop-out 0.8.1.1 0.85.1.1 0.3.0.6 coil 50/60 coil coil 50/60 coil coil 50/60 coil coil 50/60 coil 0.75 0.75 12.22 4.19 Average consumption Inrush Sealed Inrush Sealed Heat dissipation Operating time Mechanical life millions operating cycles 50/60 Closing Opening coil 50/60 coil Maximum operating rate operating cycles hour 3600 ambient temperature Protection ensured connection cross-sections shown page 2/33 connection cable. least favourable direction, without change contact state (coil supplied Ue). closing time measured from moment coil supply switched initial contact main poles. opening time measured from moment coil supply switched moment main poles separate. Selection: pages 1/35 2/34 References: pages Dimensions: pages 2/44 2/47 Schemes: pages 2/48 2/49 Schneider Electric DT60 D115 D150 25.400 25.400 25.400 1000 25.400 1000 25.400 1000 25.400 1000 1000 1000 25.400 1100 1100 1000 25.400 1100 1100 1100 1000 25.400 1260 1100 1100 1000 25.400 1660 1400 1400 1200 pages 2/52 2/53, fuse ratings corresponding associated thermal overload relay 12.5 12.5 13.5 12.690 24.660 24.500 0.8.1.1 0.85.1.1 0.3.0.6 0.75 0.75 12.22 4.19 3600 0.85.1.1 0.3.0.6 0.8.1.1 0.85.1.1 0.3.0.6 0.75 0.75 6.10 20.26 8.12 3600 20.26 8.12 3600 20.26 8.12 3600 20.35 6.20 3600 20.35 6.20 3600 0.85.1.1 0.3.0.5 0.8.1.15 50/60 0.3.0.5 280.350 2.18 280.350 2.18 20.50 6.20 2400 280.350 2.18 280.350 2.18 3.4.5 20.35 40.75 1200 Schneider Electric 2/35 Characteristics (continued) TeSys contactors Model d.c. control circuit characteristics Type contactor LC1D09.D38 DT20.DT60 Conforming 947-1 Conforming Control voltage limits Operational Standard coil Wide range coil Drop-out 12.440 0.7.1.25 0.1.0.25 Inrush Sealed Average operating time Closing 0.85.1.1 0.75.1.2 0.1.0.3 85.110 95.130 0.75.1.2 0.15.0.4 2.4.5.1 20.35 LC1- LP1D40.D65 12.440 LP1-D80 LC1-D115 LC1-D150 24.440 Rated control circuit voltage (Uc) Rated insulation voltage Average consumption Opening 20.35 20.35 40.75 Note: arcing time depends circuit switched poles. normal 3-phase applications, arcing time usually less than load isolated from supply after time equal opening time arcing time. Time constant (L/R) Mechanical life Maximum operating rate ambient temperature millions operating cycles operating cycles hour 3600 3600 3600 1200 consumption control circuit characteristics Rated insulation voltage Conforming 60947-1 Conforming Maximum voltage Average consumption d.c. control circuit Wide range coil (0.7.1.25 Inrush Sealed 1.25 0.1.0.3 Operating time Voltage limits control circuit Closing Opening Operational Drop-out Time constant (L/R) Mechanical life millions operating cycles Maximum operating rate ambient temperature ops/h 3600 Operating times depend type contactor electromagnet control mode. closing time measured from moment coil supply switched initial contact main poles. opening time measured from moment coil supply switched moment main poles separate. least favourable direction, without change contact state. Selection: pages 1/35 2/36 References: pages Dimensions: pages 2/44 2/47 Schemes: pages 2/48 2/49 Schneider Electric Characteristics (continued) TeSys contactors Model Contactor integral auxiliary contact characteristics Linked contacts conforming draft standard 947-4-5 Mirror contact Rated operational voltage (Ue) Rated insulation voltage (Ui) Each contactor contacts mechanically linked same movable contact holder contact each contactor represents state power contacts connected PREVENTA safety module Conforming 947-1 Conforming Conventional thermal current (Ith) Operating current frequency Minimum switching capacity 10-8 Short-circuit protection Rated making capacity Short-time rating min. min. Conforming 60947-5-1 Conforming 60947-5-1, Permissible Guaranteed between contacts a.c. supply categories AC-14 AC-15 Electrical life (valid 3600 operating cycles/hour) inductive load such coil electromagnet: making power (cos 0.7) times power broken (cos 0.4). 1050 DC-13 Millions operating cycles 25.400 fuse: 140, energisation de-energisation ambient temperature Insulation resistance Non-overlap time Contact operating power conforming 60947-5-1 d.c. supply category DC-13 Electrical life (valid 1200 operating cycles/hour) inductive load such coil electromagnet, without economy resistor, time constant increasing with load. million operating cycles million operating cycles million operating cycles AC-15 Millions operating cycles 1440 Current broken Current broken Selection: pages 1/35 Schneider Electric References: pages Dimensions: pages 2/44 2/47 Schemes: pages 2/48 2/49 2/37 Characteristics TeSys contactors Auxiliary contact blocks without dust damp protected contacts model contactors Contact block type LAD-N LAD-T LAD-R LAD-8 Environment Conforming standards Product certifications Protective treatment Degree protection Ambient temperature around device Conforming Conforming 0106 Storage Operation Permissible operation Maximum operating altitude Without derating Phillips Flexible solid cable with without cable Flexible solid cable without cable 947-5-1, 63-140, 0660, 60947-5-1 "TH" Protection against direct finger contact 60.+ 40.+ 3000 Min.: max.: Max.: Cabling Connection spring terminals Instantaneous time delay contact characteristics Number contacts Rated operational voltage (Ue) Rated insulation voltage (Ui) Conforming 60947-5-1 Conforming Conventional thermal current (Ith) Frequency operational current Minimum switching capacity min. min. Short-circuit protection Rated making capacity Short-time rating ambient temperature 25.400 140; energisation de-energisation) 40.+ 40.+ Conforming 60947-5-1 0660. fuse Conforming 60947-5-1, Permissible for: Guaranteed between contacts Guaranteed between LAD-C22 Ambient temperature operation Repeat accuracy Drift million operating cycles Drift depending ambient temperature Insulation resistance Non-overlap time Overlap time Time delay (LAD-T, contact blocks) Accuracy only valid setting range indicated front face 0.25 0.25 Mechanical durability Operational power contacts millions operating cycles page 2/40 References: pages 2/17 2/18 2/38 Dimensions: pages 2/44 2/45 Schemes: pages 2/48 2/49 Schneider Electric Characteristics TeSys contactors Auxiliary contact blocks with dust damp protected contacts model contactors Contact block type LA1-DX LA1-DX protected LA1-DY protected Environment Conforming standards Product certifications Protective treatment Degree protection Ambient temperature Cabling Conforming Conforming 0106 Storage operation Phillips Flexible solid cable with without cable 947-5-1, 0660 "TH" Protection against direct finger contact 25.+ Min.: Max.: Number contacts Contact characteristics Rated operational voltage (Ue) Rated insulation voltage (Ui) Conforming 947-5-1 Conforming Conventional thermal current (Ith) Maximum operational current (Ie) Frequency operational current Minimum switching capacity min. min. Short-circuit protection Rated making capacity Short-time rating ambient temperature Gold Single break with crossed bars Gold Single break with crossed bars 25.400 140; Gold Single break with crossed bars Conforming 60947-5-1. fuse Conforming 60947-5-1, Permissible for: millions operating cycles Insulation resistance Mechanical durability Materials technology used dust damp protected contacts References: page 2/17 Schneider Electric Dimensions: pages 2/44 2/45 Schemes: pages 2/48 2/49 2/39 Characteristics TeSys contactors Auxiliary contact blocks with dust damp protected contacts model contactors Operational power contacts (conforming 60947-5-1) a.c. supply, categories AC-14 AC-15 Electrical durability (valid 3600 operating cycles/hour) inductive load such coil electromagnet: making power (cos 0.7) times power broken (cos 0.4). 1050 1440 million operating cycles million operating cycles million operating cycles Millions operating cycles Current broken d.c. supply, category DC-13 Electrical durability (valid 1200 operating cycles/hour) inductive load such coil electromagnet, without economy resistor, time constant increasing with power. million operating cycles million operating cycles million operating cycles Millions operating cycles Current broken References: pages 2/17 2/18 2/40 Dimensions: pages 2/44 2/45 Schemes: pages 2/48 2/49 Schneider Electric Characteristics TeSys contactors Control modules, coil suppressor modules mechanical latch blocks model contactors Environment Conforming standards Product certifications Protective treatment Degree protection Ambient temperature around device Conforming Conforming 0106 Storage Operation Permissible operation 947-5-1 "TH" Protection against direct finger contact 40.+ 25.+ 25.+ "Auto Stop" control modules Recommendation Rated insulation voltage Rated operational voltage Protection Built-in protection Indication Electrical durability Auto selector switch must only operated with Start Stop ("O" "I") switch position Conforming 60947-5-1 Conforming 60947-5-1 Against electric shocks Contactor coil suppression integral operating cycles varistor Illuminates when contactor coil energised 20,000 Coil suppressor modules Module type Type protection LA4-DA LAD-4RC circuit LA4-DB LAD-4T Bidirectional peak limiting diode 24.72 LA4-DC Diode LA4-DE LAD-4V Varistor Rated control circuit voltage (Uc) Maximum peak voltage Natural frequency 24/48 50/127 110/240 380/415 24.415 12.250 24.250 Mechanical latch blocks Mechanical latch block type mounting contactor LA6-DK10 LC1D40.D65, LP1-D65 Conforming 947-5-1 50/60 unlatching operating cycles/hour 24.415 LAD-6K10 LC1-D09.D38, DT20.DT60 LA6-DK20 LC1-D80.D150 LP1-D80 LC1-D115 24.415 Certification Rated insulation voltage Rated control circuit voltage Power required Maximum operating rate On-load factor Mechanical durability 1200 1200 millions operating cycles Unlatching manually operated locally electrically controlled remote operation. LA6-DK LAD-6K latch coil LC1-D operating coil must energised simultaneously. duration LA6-DK LAD-6K LC1-D control signals must References: pages 2/18 2/21 Schneider Electric Dimensions: pages 2/44 2/45 Schemes: pages 2/48 2/49 2/41 Characteristics TeSys contactors Electronic serial timer modules model contactors Module type LA4-DT (On-delay) LA4-DR (Off-delay) LC1-D Environment Conforming standards Product certifications Protective treatment Degree protection Ambient temperature around device Rated insulation voltage (Ui) Cabling 255-5 "TH" Protection against direct finger contact 40.+ 25.+ 25.+ Conforming Conforming 0106 Storage Operation operation Conforming 60947-5-1 Phillips Flexible solid cable with without cable Min.: Max.: Control circuit characteristics Built-in protection Rated control circuit voltage (Uc) Permissible variation Type control input Suppression contactor varistor varistor 24.250 0.8.1.1 mechanical contact only varistor bidirectional peak limiting diode 24.250 0.8.1.1 mechanical contact only, connecting cable Time delay characteristics Timing ranges Repeat accuracy Reset time Immunity micro-breaks Minimum control pulse duration Indication time delay 0.40 During time delay period After time delay period During time delay period After time delay period 0.1.2; 1.5.30; 25.500 minimum) Illuminates during time delay period 0.1.2; 1.5.30; 25.500 minimum) Illuminates during time delay period Switching characteristics (solid state type) Maximum power dissipated Leakage current Residual voltage Overvoltage protection Electrical durability millions operating cycles joule joule Operating diagrams LA4-DT "On-delay" electronic timers LA4-DR "Off-delay" electronic timers supply (A1-A2) supply (A1-A2) Time delay output Contactor coil Control (A2-B2) Time delay output Contactor coil References: page 2/21 2/42 Dimensions: pages 2/44 2/45 Schemes: pages 2/48 2/49 Schneider Electric Characteristics TeSys contactors Interface modules model contactors Environment Conforming standards Product certifications Protective treatment Degree protection Ambient temperature around device Conforming Conforming 0106 Storage Operation Permissible operation 255-5 "TH" Protection against direct finger contact 40.+ 25.+ 25.+ Other characteristics Module type LA4DFBQ With relay Conforming 60947-5-1 Conforming 60947-5-1 LA4DFB With relay LA4DFE With relay LA4LA4DLB With relay override LA4DWB Solid state Rated insulation voltage Rated operational voltage Indication input state Input signals integral which illuminates when contactor coil energised Control voltage (E1-E2) Permissible variation Current consumption State guaranteed State guaranteed 17.30 diode diode With coil: 24.250 100.250 380.415 LC1-D40.D115 LC1-D09.D38, DT20.DT60 17.30 33.60 17.30 33.60 5.30 Built-in protection Electrical durability 220/240 Maximum immunity time micro-breaks Power dissipated Direct mounting without contactor Against reverse polarity input millions operating cycles LC1-D40.D150 LC1-D40.D150 LC1-D09.D38, DT20.DT60 LC1-D09.D38, DT20.DT60 Mounting with cabling adaptor LAD-4BB With coil: 24.250 380.415 Total operating time contactor) Operating times depend type contactor electromagnet control mode. closing time measured from moment coil supply switched initial contact main poles. opening time measured from moment coil supply switched moment main poles separate. LC1-D09.D38, DT20.DT60 20.30 16.24 Min.: Min.: LC1-D40.D65 LC1-D80 With LA4-DF, Cabling Phillips Flexible solid cable with without cable 28.34 20.24 28.43 18.32 References: page 2/21 Schneider Electric Dimensions: pages 2/44 2/45 Schemes: pages 2/48 2/49 2/43 Other recent searchesUF1000 - UF1000 UF1000 Datasheet UF1008 - UF1008 UF1008 Datasheet TDA8175 - TDA8175 TDA8175 Datasheet RLP-158+ - RLP-158+ RLP-158+ Datasheet LSD815 - LSD815 LSD815 Datasheet 65-XX - 65-XX 65-XX Datasheet RP4-PF - RP4-PF RP4-PF Datasheet LA92B - LA92B LA92B Datasheet 2EG-1 - 2EG-1 2EG-1 Datasheet DNB63 - DNB63 DNB63 Datasheet
Privacy Policy | Disclaimer |