Accurate reliable control motors Increase your productivity, adop


  

Download PDF



Top Searches for this datasheet


zener diode f7 850 - zener diode f7 850  
vrb3 - vrb3  
voltage suppression LT6 - voltage suppression LT6  
VCF01* - VCF01*  
VCD2 - VCD2  
VCD02 - VCD02  
V23037-A0005-A101 - V23037-A0005-A101  
types GV2, GV3 and GV7 - types GV2, GV3 and GV7  
tt170 - tt170  
TT160 - TT160  
TESYS PROTECTION COMPONENTS GV2 LE AND GV2 L - TESYS PROTECTION COMPONENTS GV2 LE AND GV2 L  
tesys d contactors - tesys d contactors  
tesys complete set of star delta starter - tesys complete set of star delta starter  
TeSys circuit-breakers - TeSys circuit-breakers  
tesys* - tesys*  
star delta wiring lc1d - star delta wiring lc1d  
star delta starter using lc1d - star delta starter using lc1d  
sodium vapor lamp - sodium vapor lamp  
schneider LRD 08 - schneider LRD 08  
schneider LC1-D80 - schneider LC1-D80  
schneider LC1-D38 - schneider LC1-D38  
schneider LC1-D25 - schneider LC1-D25  
schneider LC1-D09 - schneider LC1-D09  
schneider ladt2 - schneider ladt2  
SCHNEIDER LADN31 - SCHNEIDER LADN31  
schneider GV2 - schneider GV2  
Schneider Electric thermal-magnetic motor circuit - Schneider Electric thermal-magnetic motor circuit  
Schneider Electric lc1-d95 - Schneider Electric lc1-d95  
Schneider Electric - Schneider Electric  

TeSys range provide more simplicity, compactness, openness flexibility many evolutions items your productivity.
Accurate reliable control motors
Increase your productivity, adopt solutions which help simplify setting-up.
Motor starters Ready-to-use component combinations, designed work together perfect harmony. Safe operation level coordination guaranteed major manufacturer. Power circuit control wide range components. Solutions variety power control applications: lighting, capacitor switching, heating, changeover contactor pairs, resistive loads, upstream protection.
Contents
Motor control components
TeSys Motor starters
TeSys contactors 5/11 Contactors, TeSys Variable composition contactors, TeSys TeSys protection components 5/12 5/33 Thermal-magnetic circuit-breakers Magnetic circuit-breakers Fuse carriers, switch-disconnector-fuses Thermal overload relays Electronic thermal overload relays Electronic overload relays Starter-controller, TeSys Multifunction protection relays Switch disconnectors Mini Vario Vario TeSys starters 5/34 5/41 Combination motor starters Starter-controller, TeSys Controller, TeSys Enclosed motor starters TeSys installation system 5/42 5/43 motor starter components with spring terminals, TeSys Quickfit technology
TeSys circuit-breakers, LC1D 40/50/65 contactors, LRD3 thermal relays equiped with terminal block:
EverLink
Long lasting connection quality. Schneider Electric patented technology.
TeSys Motor management system
Components power control applications 5/44 5/50
TeSys protected
TeSys advanced motor management protection system. able guard against motor malfunctions: overland, current peak, excessive consumption, etc.
Lighting, capacitor switching, heating, changeover contactor pairs
TeSys Communication modules
With open communication across CANopen, Profibus Modbus, AS-interface, Advantys STB, DeviceNet Ethernet networks, TeSys openness mind.
TeSys
Contactors
0.06.5.5
Connections
screw clamp terminals
Rated operational current Rated operational power category Contactor type (1)*
AC-3 440V) AC-1 220/240 380/400 V.415/440 660/690 V.500
LC2-K06 LP2-K06 LP5-K06
LP1-K09 LC2-K09 LP2-K09 LP5-K09
LP1-K12 LC2-K12 LP2-K12 LP5-K1
Reversing contactor type with mechanical interlock spring terminals
figure before voltage code. Example becomes Faston connectors, 6.35
figure before voltage code. Example becomes solder pins printed circuit boards figure before voltage code. Example becomes Basic reference, completed adding auxiliary contact, auxiliary contact. Basic reference completed adding coil voltage
Standard control circuit voltages
supply Contactors LC1-K (0.8.1.15 (0.85.1.1UC)
Volts 50/60 Volts 50/60 supply
380/400
400/415
200/208
220/230 660/690
230/240
Example complete reference LC1-K0910P7
Contactors LP1-K (0.8.1.15 Volts Code
Coil with integral suppression device available, code required. Example consumption Contactors LP4-K (0.7.1.30 Uc), coil suppression standard
Volts Code
Example complete reference LC1-K0910BD
Other versions: please consult your Schneider Electric agency.
Auxiliary contact blocks
instantaneous, screw clamp connections LC1, LP1-K, LC1, LP1-K
Composition Reference
electronic time delay
2N/O LA1-KN20
2N/C
1N/O 1N/C LA1-KN1
4N/O LA1-KN40
3N/O 1N/C LA1-KN3
2N/C 2N/C LA1-KN2
1N/O 3N/C LA1-KN13
4N/C
LA1-KN0
LA1-KN04
Relay outputs, with common point changeover contact, 24.48, maximum Control voltage 0.85.1.1Uc Maximum switching capacity Operating temperature -10.+ 60°C Reset time: after time delay period Type Timing range Composition Voltage Reference On-delay 1.30 24.48 LA2-KT2E 110.240 LA2-KT2U
Suppressor modules
LC1, LP1-K Type Voltage Reference Varistor 12.24 LA4-KE1B 32.48 LA4-KE1E 50.129 LA4-KE1FC 130.250 LA4-KE1UG Diode zener 12.24 LA4-KC1B 32.48 LA4-KC1E 220.250 LA4-KA1U
Other versions: please consult your Schneider Electric agency.
TeSys
Contactors
0.06.75
Connections
screw clamp terminals connectors
Rated operational voltage Rated operational current Rated operational power category AC-3 440V) AC-1 220/240 380/400 415/440 660/690 1000 Contactor type Reversing contactor type with mechanical interlock
spring terminals
LC1-D09 LC2-D09 LC1-D12 LC2-D12 LC1-D18 LC2-D18 LC1-D25 LC2-D25 18.5 18.5 LC1-D32 LC2-D32 18.5 18.5 18.5 18.5 LC1-D38 LC2-D38
figure before voltage code. Example LC1-D09P7 becomes LC1-093P7
lug-clamps
figure before voltage code. Example LC1-D09P7 becomes LC1-096P7
Faston connectors
6.35 (power) 6.35 (control) only
figure before voltage code. Example LC1-D09P7 becomes LC1-099P7 Basic reference completed adding coil voltage
Standard control circuit voltages
supply Volts Contactors LC1-D09.D150 (coils D115 D150 with integral suppression device fitted standard)
50/60 Contactors LC1-D80.D115 supply Volts
Contactors LC1-D09.D65A (coils with integral suppression device fitted standard) 0.75.1.25 Contactors LC1-D80.D95 0.85.1.1 0.75.1.2
Contactors LC1-D115 D150 (coils with integral suppression device fitted standard)
0.75.1.2 consumption
Contactors LC1-D09.D38 (coils with integral suppression device fitted standard) Volts 0.7.1.25 Example complete reference LC1-D09P7
Other versions: please consult your Schneider Electric agency.
18.5 LC1-D40A LC2-D40A LC1-D50A LC2-D50A 18.5 LC1-D65A LC2-D65A
supply, supply LC1-D80 LC2-D80 LC1-D95 LC2-D95 LC1-D115 LC2-D115 LC1-D150 LC2-D150
Mounting accessories 3-pole reversing contactors
identical contactors with screw clamp terminals connectors, horizontally mounted Mechanical interlock
with electrical interlocking contactors
connections LAD-9R1V LA9-D8069 LA9-D8069 LA9-D11569 LA9-9R1 LAD-9R3 LA9-D8069 LA9-D8069 Mechanical interlock included LA9-D4002 LA9-D8002 LA9-D11502 included included LA9-D50978 LA9-D80978
LC1-D09.D38
with integral electrical interlocking
LC1-D80 LC1-D80 LC1-D115 D150
without electrical interlocking
LC1-D09.D38 LC1-D40A.D65A LC1-D80 LC1-D80
Mechanical latch blocks
Clip-on front mounting, manual electrical unlatching control contactor LC1-D09.D65A LC1-DT20.DT80 LC1-D80.D150 LC1-D80 D115 LC1-D115 Reference Standard control circuit voltages BEFMQ BEFMQ
Other versions: please consult your Schneider Electric agency.
TeSys
Contactors
Auxiliary contacts
Contact type instantaneous, connection screw terminals
Front mounting Contact "N/O" "N/C" "N/O" "N/C" "N/O" "N/C" LADN10 LADN01 LADN11 LADN20 LADN02 LADN22 LADN13 LADN31 LADN40 LADN04 Side mounting LAD8N11 LAD8N20 LAD8N02
Block mounting References
"N/O" "N/C" "N/O" "N/C" "N/O" "N/C" "N/O" "N/C"
Type contacts
Block mounting Temporisation References On-delay Off-delay
Time delay, connection screw terminals
Front mounting 0.1.3 LADT0 LADR0 0.1.30 LADT2 LADR2 10.180 LADT4 LADR4
Maximum number auxiliary contacts that fitted
Instantaneous
Type Number poles size LC1D09.D38 LC1D40A.D65A LC1D80.95 (50/60Hz) Side mounting left side right side Front mounting contact contacts contacts
Time delay
Front mounting
LC1D80.95 60Hz) LC1D115 D150 LC1DT20.DT40 LC1DT60A.D80A LC1D115 LC1D09.D38 LC1D40A.D65A LC1D80 LC1D115 D150 LC1DT20.DT40 LC1DT60A.D80A LC1D115
consumption
LC1D09.D38 LC1DT20.DT40
Other versions: please consult your Schneider Electric agency.
TeSys
Contactors
Suppressor modules
Type module
Mounting with contactor References Voltage 24.48 50.127 110.240 380.415
circuits (Resistor-Capacitor)
Side clip-on D09.D38(3P) DT20.DT40(4P) LAD4RCE LAD4RCG LAD4RCU Front clip-on LAD4RC3E LAD4RC3G LAD4RC3U LAD4RC3N Screw fixing LA4DA2E LA4DA2G LA4DA2U LA4DA2N
D40A.D65A(3P) DT60A.DT80A(4P) D80.D150(3P) D40.D115(4P)
Type module
Mounting with contactor References Voltage 24.48 50.127 110.240 24.48 50.127 110.240
Varistors (peak limiting)
Side clip-on D09.D38(3P) DT20.DT40(4P) LAD4VE LAD4VG LAD4VU Front clip-on LAD4V3E LAD4V3G LAD4V3U Screw fixing LA4DE2E LA4DE2G LA4DE2U LAD4DE3E LAD4DE3G LAD4DE3U
D40A.D65A(3P) DT60A.DT80A(4P) D80.D150(3P) D40.D115(4P)
Type module
Mounting with contactor References Voltage 24.250
Flywheel diodes
Side clip-on D09.D38(3P) DT20.DT40(4P) LAD4DDL Front clip-on LAD4D3U Screw fixing LAD4DC3U
D40A.D65A(3P) DT60A.DT80A(4P) D80.D150(3P) D40.D115(4P)
Type module
Mounting with contactor References Voltage
Bidirectional peak limiting diode
Side clip-on D09.D38(3P) DT20.DT40(4P) LAD4TB LAD4TBDL LAD4TS LAD4TSDL LAD4TGDL LAD4TUDL LAD4TXDL Front clip-on LAD4T3B LAD4T3B LAD4T3S LAD4T3S LAD4T3G LAD4T3U LAD4T3R Screw fixing LA4DB2B LA4DB2S LA4DB3B LA4DB3S
D40A.D65A(3P) DT60A.DT80A(4P) D80.D150(3P) D40.D115(4P)
Other versions: please consult your Schneider Electric agency.
TeSys
Contactors
90.450
Rated operational current Rated operational voltage Number poles Rated operational power category
AC-3 440V) AC-1
LC1-F225 LC2-F225
LC1-F265 LC2-F265
LC1-F330
220/240 380/400 660/690 1000
LC1-F185 LC2-F185
Contactor type*
Reversing contactor type* Basic reference completed adding coil voltage
Standard control circuit voltages
supply Volts Contactors LC1-F115.F225(0.85.1.1UC) (coil LX1) (coil LX1) 40.400 (coil LX9) Contactors LC1-F265.F330U7 40.400 (coil LX1) Contactors LC1-F400.F630U7 40.400 (coil LX1) Contactor LC1-F780U7 40.400 (coil LX1)
R6U7 V7Y7
Contactor LC1-F800U7 40.400 (coil LX1) supply Volts Contactors LC1-F115.F330(0.85.1.1UC) (coil LX4-F) Contactors LC1-F400.F630(0.85.1.1UC) (coil LX4-F) Contactor LC1-F780(0.85.1.1UC) (coil LX4-F) Contactor LC1-F800(0.85.1.1UC) (coil LX4-F) Example: contactor with coil, order LC1-F630F7 LC1-F630
Other versions: please consult your Schneider Electric agency.
LC1-F400
LC1-F500 customer assembly
LC1-F630
LC1-F780
LC1-F800
Auxiliary contact blocks
instantaneous
dust damp protected contacts Composition Reference LAD-N11 LAD-N20 LAD-N02 Composition LAD-N22 LAD-N13 LAD-N40 LAD-N04 LAD-N31 LAD-C22 Reference Composition LA1-DX20 LA1-DY20 LA1-DZ40 LA1-DZ31 Reference
time delay 1N/O
Composition Reference LAD-N10 LAD-N0
Type On-delay
Range 0.1.3 0.1.30 10.180 1.30
Reference LAD-T0 LAD-T2 LAD-T4 LAD-S2 LAD-R0 LAD-R2 LAD-R4
Off-delay
0.1.3 0.1.30 10.180
Mounting accessories 3-pole reversing contactors motor control
identical contactors, horizontally mounted Mechanical interlock with electrical interlocking contactors Contactor type LC1-F115 LC1-F150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 LC1-F800 connections LA9-FF976 LA9-F15076 LA9-FG976 LA9-F22576 LA9-FH976 LA9-FJ976 LA9-FJ976 LA9-FK976 LA9-FL976 Mechanical interlock LA9-FF970 LA9-FF970 LA9-FG970 LA9-FG970 LA9-FJ970 LA9-FJ970 LA9-FJ970 LA9-FJ970 LA9-FL970
Other versions: please consult your Schneider Electric agency.
TeSys
Contactors
400.900
Rated operational current Rated operational voltage Number poles Rated operational power category
AC-3 440V) AC-1
1000 1250
1500 2000
1800 2750A
220/240 380/400 660/690 1000
instantaneous contact configurations
N/O, N/C, Contactor type* LC1-BL LC1-BM LC1-BP LC1-BR Basic reference completed adding coil voltage, followed instantaneous contact configuration.
Standard control circuit voltages (for other voltages, please consult your Regional Sales Office) Volts 50.400
Example: order 1500 contactor with coil with N/C, select LC1-BP33G3
Mounting accessories
Description support bracket contactor LC1-BL LC1-B Reference LA9-B103 EZ2-LB060
mounting centres Mechanical interlock locking device components
Other versions: please consult your Schneider Electric agency.
5/10
TeSys
CV1-B, CV3-B
Reference compiled customer
Contactor type, according required supply supply V/pole supply 1000 supply V/pole Contactor rating CV1: CV1: CV1: CV1: CV1: CV1: 1000 Number poles (PN1 main poles main poles CV3) Normally Open main poles Normally Closed main poles main poles Operational current 1000 Control circuit voltage Operating frequency 50/60 economy resistor Instantaneous auxiliary contacts Normally Open Normally Closed Without instantaneous contact On-delay Off-delay CV3: CV3: CV3: CV3: CV3:
Contactors variable composition
CV1-B 80.1000 CV3-B 80.500
CV1-B CV3-B
Example single-phase capacitor switching: pole Control circuit 1N/C auxiliary contacts: CV1-BF1F0ZM511. heating circuits, d.c. supply poles Control circuit On-delay auxiliary contacts: CV3-BG2W0ZED10J
Other versions: please consult your Schneider Electric agency.
TeSys
GV2-ME, GV2-P
Thermal-magnetic circuit-breakers
0.06.15
Thermal-magnetic circuit-breakers GV2-ME GV2-P connection screw clamp terminals
GV2-ME with pushbutton control, GV2-P control rotary knob Standard power ratings 3-phase motors 50/60 category AC-3 400/415 0.06 0.37 0.55 0.75 18.5 18.5 0.37 0.55 0.75 18.5 18.5
Setting range thermal trips 0.1.0.16 0.16.0.25 0.25.0.40 0.40.0.63 0.40.0.63 0.63.1 1.1.6 1.1.6 1.1.6 1.6.2.5 1.6.2.5 2.5.4 2.5.4 2.5.4 2.5.4 4.6.3 4.6.3 6.10 6.10 6.10 6.10 9.14 9.14 9.14 9.14 13.18 13.18 17.23 17.23 20.25 20.25 24.32 24.3
Magnetic tripping current 20%) 22.5 22.5 22.5 33.5 33.5
Reference
GV2-ME01 GV2-ME02 GV2-ME03 GV2-ME04 GV2-ME04 GV2-ME05 GV2-ME06 GV2-ME06 GV2-ME06 GV2-ME07
GV2-P01 GV2-P02 GV2-P03 GV2-P04 GV2-P04 GV2-P05 GV2-P06 GV2-P06 GV2-P06 GV2-P07
0.09 0.12 0.18 0.25 0.37 0.55
0.75 0.75
GV2-ME08 GV2-P08 GV2-ME08 GV2-P08 GV2-ME10 GV2-P10 GV2-ME14 GV2-P14 GV2-ME14 GV2-P14 GV2-ME16 GV2-P16 GV2-ME16 GV2-P16 GV2-ME20 GV2-P20 GV2-ME21 GV2-P21 GV2-ME22 GV2-P22 GV2-ME32 GV2-P3
combined with recommended contactor
Thermal-magnetic circuit-breakers GV2-ME connection spring terminals
figure reference. Example GV2-ME22 becomes GV2-ME223
Thermal-magnetic circuit-breakers GV2-ME connection ring terminals
figure reference. Example GV2-ME32 becomes GV2-ME326
Common accessories GV3, page 5/15
Other versions: please consult your Schneider Electric agency.
TeSys
GV2-L, GV2-LE
Magnetic circuit-breakers
0.06
Magnetic circuit-breakers GV2-LE GV2-L connection screw clamp terminals
GV2-LE control rocker lever, GV2-L control rotary knob Standard power ratings 3-phase motors 50/60 category AC-3 400/415 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.75 0.37 0.55 0.75 18.5 18.5 0.37 0.55 0.75 18.5 18.5 Magnetic protection rating 0.63 0.63 Tripping current 22.5 22.5 33.5 33.5 33.5 LR2-K0302 LR2-K0304 LRD-03 LR2-K0304 LRD-04 LR2-K0305 LRD-04 LR2-K0305 LRD-05 LR2-K0306 LRD-05 LR2-K0306 LRD-06 LR2-K0306 LRD-05 LR2-K0307 LRD-06 LR2-K0307 LRD-06 LR2-K0308 LRD-07 LR2-K0308 LRD-08 LR2-K0310 LRD-08 LR2-K0312 LRD-08 LR2-K0312 LRD-10 LR2-K0314 LRD-12 LR2-K0316 LRD-14 LRD-14 LRD-14 LRD-16 LRD-16 LR2-K0321 LRD-16 LRD-21 LRD-21 LRD-22 LRD-22 LRD-22 LRD-22 LRD-32 LRD-32 GV2-LE03 GV2-LE03 GV2-L03 GV2-LE04 GV2-L04 GV2-LE04 GV2-L04 GV2-LE05 GV2-L05 GV2-LE05 GV2-L05 GV2-LE05 GV2-L05 GV2-LE05 GV2-L05 GV2-LE06 GV2-L06 GV2-LE06 GV2-L06 GV2-LE07 GV2-L07 GV2-LE08 GV2-L08 GV2-LE08 GV2-L08 GV2-LE08 GV2-L08 GV2-LE10 GV2-L10 GV2-LE14 GV2-L14 GV2-LE14 GV2-L14 GV2-LE14 GV2-L14 GV2-LE16 GV2-L16 GV2-LE16 GV2-L16 GV2-LE20 GV2-L20 GV2-LE22 GV2-L22 GV2-LE22 GV2-L22 GV2-LE32 GV2-L32 association with thermal overload relay Reference
Common accessories GV3, page 5/15
Other versions: please consult your Schneider Electric agency.
5/13
TeSys
GV3-P/GV3-L
Circuit-breakers
Thermal-magnetic 5,5.30 with EverLink terminal blocks
Thermal-magnetic circuit-breakers GV3-P connection EverLink terminal blocks
Control rotary knob Standard power ratings 3-phase motors 50/60 category AC-3 400/415 18,5 660/690 18,5
Setting range thermal trips 9.13 12.18 17.25 23.32 30.40 37.50 48.65
Reference
GV3-P13 GV3-P18 GV3-P25 GV3-P32 GV3-P40 GV3-P50 GV3-P65
18,5
Thermal-magnetic circuit-breakers GV3-P connection ring terminals
figure reference. Example GV3-P13 becomes GV3-P136 motor starter solution, only EverLink terminal block, figure reference. Example GV3P65 becomes GV3P65
Magnetic 11.30 with EverLink terminal blocks
Magnetic circuit-breakers GV3-L connection EverLink terminal blocks
Control rotary knob Standard power ratings 3-phase motors 50/60 category AC-3 400/415 18,5 18,5
Associated equipment Thermal overload relay LRD-22 LRD-32 LRD-3355 LRD-3357 LRD-3359
Circuit-breaker Short-circuit protection Rating Reference GV3-L25 GV3-L32 GV3-L40 GV3-L50 GV3-L65
18,5
Magnetic circuit-breakers GV3-L connection ring terminals
figure reference. Example GV3-L25 becomes GV3-L256 motor starter solution, only EverLink terminal block, figure reference. Example GV3L65 becomes GV3L651 screw
Add-on blocks accessories
Add-on blocks (front)
Contact type
Fault signalling contact instantaneous auxiliary contact
(fault) GV-AED011 (fault) GV-AED10
Accessories
Type
contactor type terminals LAD96575
IP20 cover type terminals LAD96570
3-pole busbars
2-pole busbars
"Wide spacing" type cover GV3G66
Side side mounting busbars GV3S
GV3G364
GV36264
Common add-on blocks accessories GV3, page 5/15 spring terminal version reference. Example GV-AED011 becomes GV-AED0113
Other versions: please consult your Schneider Electric agency.
5/14
TeSys
GV2/GV3
Circuit-breakers
Accessories
Accessories GVCombination block mounting Sets 3-pole busbars Number tap-offs Pitch Protective cover unused busbar outlets Terminal blocks supply more GV2-G busbar sets Padlockable external operator (150 Padlocking Handle Legend plate GV2-ME/P/L GV2-LE GV3-P/L "On" "Off" position black blue GV2-AP01 GV2-AP03 GV3-AP01 "Off" position yellow GV2-AP02 GV3-AP02 connection from GV1-G09 fitted with current limiter GV1-L3 (GV2-ME GV2-P) GV1-G05 GV1-G10 GV2-G245 GV2-G345 GV2-G445 GV2-G254 GV2-G354 GV2-G454 GV2-G554 GV2-G472 GV2-G272 LC1-K LP1-K GV2-AF01 LC1-D09.D38 GV2-AF3 LAD-31 LC1-D09.D38 GV2-AF4
Add-on blocks common
Contact blocks Contact types Instantaneous auxiliary contacts Mounting front side Fault signalling contact instantaneous auxiliary contact side Short-circuit signalling contact side Electric trips Undervoltage shunt trips Side mounting block side circuit-breaker) Voltage 100.110 110.115 120.127 200.220 220.240 380.400 415.440 Padlocking device with padlocks (padlocks supplied) shank GV2-V03 GV-AM11 fault fault GV-AD1001 GV-AD0101 GV-AD1010 GV-AD0110 GV-AE1 GV-AE11 GV-AN11 GV-AE20 GV-AN20 (fault) (fault) common point
Other versions: please consult your Schneider Electric agency.
5/15
TeSys
GV7-R
Thermal-magnetic circuit-breakers
0.75.90
Thermal-magnetic circuit-breakers GV7-R connection screw clamp terminals
Control rocker lever
Standard power ratings 3-phase motors 50/60 category AC-3 400/415 18.5 18.5 18.5 660/690 18.5 18.5
Setting range thermal trips 12.20 12.20 15.25 15.25 25.40 25.40 30.50 48.80 48.80 60.100 60.100 90.150 90.150 132.220
Reference
GV7-RE20 GV7-RS20 GV7-RE25 GV7-RS25 GV7-RE40 GV7-RS40 GV7-RE50 GV7-RE80 GV7-RS80 GV7-RE100 GV7-RS100 GV7-RE150 GV7-RS150 GV7-RE220
18.5
132.220
GV7-RS220
Other versions: please consult your Schneider Electric agency.
5/16
Add-on blocks
Contact blocks Auxiliary contacts Contact type Thermal magnetic fault discrimination 24.48 24.72 GV7-AD111 Electric trips Voltage Undervoltage trip Shunt trip mounting GV7-AD GV7-AU 50/60 GV7-AU055 GV7-AS055 GV7-AU107 GV7-AS107 GV7-AU207 GV7-AS207 GV7-AU387 GV7-AS387 110. 200. 380.440 GV7-AU525 GV7-AS525 110.240 GV7-AD112 GV7-AE1
Accessories
Terminal shields Supplied with sealing accessory Phase barriers Safety accessories used when fitting shields impossible Insulating screens Ensure insulation between connections backplate combination with contactor Allowing link between circuit-breaker contactor Rotary handles Handle Legend plate
direct extended
GV7-AC01 GV7-AC04
GV7-AC05
LC1-F115 F185 GV7-AC06 black black LC1-F225 GV7-AC07 LC1-D115 D150 GV7-AC08 yellow GV7-AP04 GV7-AP0
GV7-AP03 GV7-AP01 GV7-AP05 GV7-V0
Conversion accessory mounting enclosure door Locking device circuit-breaker fitted with rotary handle
Other versions: please consult your Schneider Electric agency.
5/17
TeSys
GV3-ME
Thermal-magnetic circuit-breakers
Thermal-magnetic circuit-breakers GV3-ME connection screw clamp terminals
Pushbutton control Standard power ratings 3-phase motors 50/60 category AC-3 400/415 660/690
Setting range thermal trips 56.80
Reference
GV3-ME80
Add-on blocks GV3-ME
Contact blocks Instantaneous auxiliary contacts breaker) Normal early break type contacts GV3-A01 GV3-A02 GV3-A03 GV3-A05 GV3-A09 220, GV3-B22 GV3-D22 380, 440, GV3-B38 GV3-D38 GV3-A06 GV3-A07
Fault signalling contact Normal early break type contacts Electric trips Voltage 110, 120, 120, GV3-B11 GV3-D11 GV1-V02 GV3-A08
Undervoltage trip Shunt trip Padlocking device Start button (for bare device) volt free terminals
Other versions: please consult your Schneider Electric agency.
5/18
TeSys
GK3-EF
Magnetic circuit-breakers
Magnetic circuit-breakers GK3-EF connection screw clamp terminals
Control rotary knob Standard power ratings 3-phase motors 50/60 category AC-3 400/415 Associated equipment Thermal min. size relay LRD-3363 Circuit-breaker Short-circuit protection Rating Reference GK3-EF80
Add-on blocks
Contact blocks Contact types On-Off signalling contacts "Control circuit test" function blocks device) mounted side GK3-EF Instantaneous fault signalling contacts blocks device) mounted side GK3-EF Fault signalling contact trip fault signalling contact fitted inside circuit-breaker. GV3-A08 GV3-A09 GK2-AX12 GK2-AX22 GK2-AX52 GK2-AX10 GK2-AX20 GK2-AX50
Accessories
Padlocking device padlocking operator, with padlocks (padlocks supplied) External operator mounting enclosure door. pushbutton yellow plate, locked position means padlocks with door locked position door locked position when padlocked GK3-AP03 GK3-AV0
Other versions: please consult your Schneider Electric agency.
5/19
TeSys
Notes
Other versions: please consult your Schneider Electric agency.
5/20
TeSys
Fuse carriers
0.5.125
Type
Rated operational voltage (Ui) Fuse size Conventional rated thermal current (ith) References Number poles 1P+N 3P+N
Fuse carriers witout indicator
31,5 DF81 DF10N DF81N DF82 DF83 DF83N DF101 DF10N DF10N DF102 DF103 DF103N DF141 DF14N DF14N DF142 DF143C DF143NC DF221 DF22N DF22N DF222 DF223C DF223NC
Type
Rated operational voltage (Ui) Fuse size Conventional rated thermal current (ith) References Number poles 1P+N 3P+N
Fuse carriers with indicator
31,5 DF81V DF81NV DF82V DF83V DF83NV DF101V DF10NV DF102V DF103V DF103NV DF141V DF14NV DF142V DF143CV DF143NCV DF221V DF22NV DF222V DF223CV DF223NCV
Accessories
Type
Fuse carrier equipped Size cartridge fuse link Number contacts References
DF22 DF14AM2 DF22AM1 DF22AM
Auxiliary early break blown fuse signalling contacts
DF14 DF14AM
Type
Fuse carrier assembled Size cartridge fuse link contents References
Fuse carrier assembly kits
31,5 pin, clips DF10AP DF10 DF14 pin, clips DF14AP DF22AP DF22
Other versions: please consult your Schneider Electric agency.
5/TeSys
LS1,
Fuse carriers
0.125
Fuse carriers
Rated operational voltage with links, a.c. supply Maximum continuous current ambient temperature with links with fuses (mm2/A) with fuses (mm2/A) Conforming standards 60947-3 947-3 Product certifications Fuse carrier type cable (mm2/A)
6/32 4/25 2.5/16 6/32 4/22 2.5/20 6/32 2.5/20 1.5/16 LS1-D3
4/25 2.5/16 4/22 2.5/20 2.5/20 1.5/16
10/50 6/40 10/50 6/35 10/40 6/32
32/125 25/100 32/125 25/100 25/100 16/80
LS1-D323
Basic blocks
Connection Rating Cartridge fuse size
spring terminals
Without LS1-D323
Number early break contacts Single-phase protection device 3-pole
Without
Without
With
Without
With
screw clamp terminals connectors
Number early break contacts 3-pole
LS1-D32 LS1-D32 LA8-D324
GK1-EK GK1-EM GK1-ES GK1-ET GK1-EW GK1-EX GK1-EV GK1-EY
GK1-FK GK1-FM GK1-FS GK1-FT GK1-FW GK1-FX GK1-FV GK1-FY
4-pole Number early break contacts 3-pole 4-pole
Other versions: please consult your Schneider Electric agency.
Operators
Handles Number poles, fuse carrier rating mounting side GK1-AP07
external side front
side GK1-AP08 side GK1-AP05 side GK1-AP06 side GK1-AP07 side GK1-AP08 Fitted standard
fuse carrier rating mounting
side DK1-FB005
Padlocking devices
fuse carrier rating Number poles Single-phase protection device Without Integral Without GK1-AV07 With GK1-AV08 Without GK1-AV08 With GK1-AV09
Links
Tubular links Number poles, fuse carrier rating Reference DK1-CB92 DK1-EB92 DK1-FA92
neutral circuit, tubular link interlocked with special device LA8-D25906. 4-pole fuse carriers GK1-50 fitted with interlocked neutral tubular link standard.
Add-on blocks
Contact blocks Contact type Instantaneous auxiliary contacts Mounting front GV-AE11 GV-AE20 GV-AE113 GV-AE203 LS1-D32 LS1-D323
Other versions: please consult your Schneider Electric agency.
5/23
TeSys
Switch-disconnector-fuses
0.1250
Switch-disconnector-fuse switch bodies
with fuses
Number poles Switch rating Fuse size Type operator:
internal external external internal external with fuses
side front side side front front side front front front GS1-DB3 GS1-DDB3 GS1-DD3
GS1-DD4 GS1-FD3 GS1-FG3 GS1-F3 GS1-FD4 GS1-FG4 GS1-F4 GS1-GD3 GS1-GG3 GS1-G3 GS1-GD4 GS1-GG4 GS1-G4 GS1-JD3 GS1-JG3 GS1-J3 GS1-JD4 GS1-JG4 GS1-J4 GS1-KD3 GS1-KG3 GS1-K3
Switch rating Fuse size
A2-A3 GS1-DDB4 GS1-GBR3 GS1-DB4 GS1-GB3 GS1-GBR4 GS1-GB4
B1-B
Type operator:
internal external side external internal external
GS1-JBR3 GS1-JB3
GS1-JBR4 GS1-JB4
GS1-LLBR3 GS1-LLBR4 GS1-LBR3 GS1-LLB3 GS1-LLB4 GS1-LB3
Switched Neutral
Fuses German market
Auxiliary "blown fuse" signalling contacts with fuses
Contact type Switch rating GS1-AF13 GS1-AF14 GS1-AF23 GS1-AF24 GS1-AF33 GS1-AF34
Fuse size Number poles
Auxiliary early break and/or signalling contacts
Switch rating Contact type 50.400 GS1-AM2 630.1250 GS1-AM3 GS1-AM4 50.400 GS1-AN11 GS1-AN22 GS1-ANT11 GS1-ANT2
Standard contacts Contacts with test facility
GS1-AM110 GS1-AM101 GS1-AM111 GS1-AM211 GS1-AM
Other versions: please consult your Schneider Electric agency.
5/24
Size
Size
Size
Size
Size
Size
1250 Size
GS1-KD4 GS1-KG4 GS1-K4
GS1-KKD3 GS1-KKG3 GS1-KK3
GS1-KKD4 GS1-KKG4 GS1-KK4
GS1-LD3 GS1-LG3 GS1-L3
GS1-LD4 GS1-LG4 GS1-L4
GS1-LLD3 GS1-LLG3 GS1-LL3
GS1-LLD4 GS1-LLG4 GS1-LL4
GS1-ND3 GS1-NG3 GS1-N3
GS1-ND4 GS1-NG4 GS1-N4
GS1-QQD3 GS1-QQD4 GS1-SD3 GS1-QQG3 GS1-QQG4 GS1-QQ3 GS1-QQ4 GS1-S3
GS1-SD4
GS1-VD3
GS1-VD4
GS1-S4 GS1-V3 1250 GS1-V4 C1.C3
B1-B
B1.B3
B1.B3
B1.B4
C1-C
GS1-LBR4 GS1-LB4 GS1-MMBR3 GS1-MMBR4 GS1-NBR3 GS1-MMB3 GS1-MMB4 GS1-NB3 GS1-NBR4 GS1-NB4 GS1-PPBR3 GS1-PPBR4 GS1-QQBR3 GS1-QQBR4 GS1-SBR3 GS1-PPB3 GS1-PPB4 GS1-QQB3 GS1-QQB4 GS1-SB3 GS1-SB4 GS1-TB3 GS1-TB4 GS1-VB3 GS1-VB4 GS1-SBR4 GS1-TBR3 GS1-TRB4 GS1-VRB3 GS1-VRB4
GS1-AF43 GS1-AF44 GS1-AF63 GS1-AF64 1250 GS1-AF73 GS1-AF74 50.400 GS1-AF GS1-AF 630.1250 GS1-AFF GS1-AFF
Other versions: please consult your Schneider Electric agency.
5/25
TeSys
Thermal overload relays
0.11.11.5
Thermal overload relays, TeSys
adjustable from 0.11 Connection screw clamp terminals, direct mounting contactors LC1-K, manual automatic reset Relay setting range Class 0.11.0.16 0.16.0.23 0.23.0.36 Fuses used with selected relay 0.25 0.25 BS88 LR2-K0301 LR2-K0302 LR2-K0303 LR2-K0304 LR2-K0305 LR2-K0306 LR2-K0307 LR2-K0308 LR2-K0310 LR2-K0312 LR2-K0314 LR2-K0316 Reference
0.36.0.54 0.54.0.8 0.8.1.2 1.2.1.8 1.8.2.6 2.6.3.7
3.7.5.5 5.5.8 8.11.5 Example LR7-K0310.
Thermal overload relays class unbalanced loads: above references LR2-K0305 LR2-K0316 only, replace prefix with LR7.
Accessories
Prewiring Allowing direct connection contact relay LRD-01.35 LR3-D01. contactor LC1-D09.D18 LC1-D25.D38 Terminal blocks clip-on mounting mounting rail (AM1-DP200) screw fixing independent mounting relay EverLink Terminal blocks LRD-01.35 LR3-D01.D35 LRD-313. LRD-365 LRD-01.35 LR3-D01.D35 relays except LRD-01.35 LR3-D01.D35 LAD-7B10 LA7-D3064 LA7-K0064 LAD-9R3 LA7-D3058 LAD-7C1 LAD-7C
Separate terminal block Terminal block adapter mounting relay beneath LC1-D115 D150 contactor Stop electrical reset Remote Tripping electrical reset device
Remote
Terminal blocks supplied with terminals protected against direct finger contact screws open "ready-to-tighten" position. order terminal block connection lug-clamps, reference becomes LA7-D30646. time which coil remote tripping electrical resetting device LA7-D03 LAD-703 remain energised depends rest time: pulse duration with rest time; maximum pulse duration with rest time Minimum pulse time Reference completed adding code indicating control circuit voltage.
Standard control circuit voltages
supply Volts 220/230 380/400 415/440 50/60 Consumption, inrush sealed supply Consumption, inrush sealed
Other versions: please consult your Schneider Electric agency.
5/26
TeSys
Thermal overload relays
0.1.140
Thermal overload relays, TeSys
adjustable from Compensated relays with manual automatic reset, with relay trip indicator, a.c. d.c. Relay setting range Fuses used with selected relay Connection screw clamp terminals connectors Class 0.10.0.16 0.25 0.16.0.25 0.25.0.40A 0.40.0.63 0,63.1 1.1.7 1.6.2.5 2.5.4 5.5.8 7.10 9.13 12.18 16.24 23.32 30.38 55.70 63.80 80.104 80.104 95.120 110.140 80.104 95.120 110.140 Class 5.5.8 7.10 9.13 12.18 17.25 23.28 25.32 55.70 63.80 Connection EverLink terminal blocks, with screws Class 9.13 12.18 17.25 23.32 30.40 37.50 48.65 9.13 Class 12.18 17.25 23.32 30.40 37.50 48.65 Class with connection lug-clamps: Select overload relay with screw clamp terminals connectors from table above following suffixes: figure relays LRD01 LRD35 LRD313 LRD365. figure relays LRD3361 LRD3365. Relays LRD43 suitable standard, with lug-clamps Independant mounting rail, order EverLink LAD96560 terminal block. With contactor BS88 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D09.D38 LC1-D12.D38 LC1-D18.D38 LC1-D25.D38 LC1-D25.D38 LC1-D32 D50.D95 D65.D95 D115 D150 D115 D150 D150 Montage Montage Montage LC1-D09.D32 LC1-D09.D32 LC1-D09.D32 LC1-D09.D32 LC1-D12.D32 LC1-D18.D32 LC1-D25 LC1-D25 LC1-D25 D65.D95 LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A LC1-D40A.D65A Reference 3361 3363 3365 4365 4367 4369 33656 33676 33696 1508 1510 1512 1514 1516 1521 1522 1530 1532 D3561 D3563 313L 318L 325L 332L 340L 350L 365L
Thermal overload relays with unbalanced loads Class with connection screw clamp terminals lug-clamp terminals:
reference selected above, change (except 4ppp) LR3D Example: LRD01 becomes LR3D01 Example with screw clamp terminal: LRD340 becomes LR3D340 Example with lug-clamp terminal: LRD3406 becomes LR3D3406
Other versions: please consult your Schneider Electric agency.
5/27
TeSys
Electronic thermal overload relays
60.630
with contactor Motor current Basic reference, completed
LC1-D 60.150 LR9-D
LC1-F 30.630 LR9-F
Relay setting range
Fuse used with selected relay
mounting beneath contactor LC1-
Compensated differential with alarm Class Class LR9-D5567 LR9-F5569 LR9-F5557 LR9-F5563 LR9-F5567 LR9-F5569 LR9-F5571 LR9-F7575 LR9-F7579 LR9-F7581 LR9-F57 LR9-F63 LR9-F67 LR9-F69 LR9-F71 LR9-F75 LR9-F79 LR9-F81 Class LR9-D5367 LR9-D5369 LR9-F5357 LR9-F5363 LR9-F5367 LR9-F5369 LR9-F5371 LR9-F7375 LR9-F7379 LR9-F738
60.100 90.150
D115 D150 D115 D150 F115.F185 F115.F185 F115.F185 F115.F185 F185.F400 F225.F500 F225.F500 F400.F630 F800
30.50 48.80 60.100 90.150 132.220 200.330
300.500 380.630
Accessories
Remote control Function Electrical reset Reset flexible cable (length Adapter door interlock mechanism Operating head pushbutton Spring return with snap-off Adjustable from Insulated terminal blocks relays F57, F63, ZA2-BZ13 blocks LA9-F103 time which coil remote electrical reset device LA7-D03 remain energised depends rest time: pulse with rest time; pulse duration with rest time; pulse duration with rest time: maximum pulse duration with rest time Minimum pulse time: Reference completed adding coil voltage code, page 5/27
Other versions: please consult your Schneider Electric agency.
Reset LA7-D305
Stop and/or Reset
LA7-D1020 ZA2-BL639 ZA2-BL43
5/28
TeSys
LR/LT
Electronic over current relays
0,3.38
Relay type
Relay setting range with contactor References 200. 100. VAC/DC VAC/DC
Electronic over current relays
TeSys LR97D 0,3.1,5 LC1D09.D38 LR97D015M7 LR97D015F7 LR97D015B LR97D015E LR97D07M7 LR97D07F7 LR97D07B LR97D07E LR97D025M7 LR97D025F7 LR97D025B LR97D025E 1,2.7 5.25 20.38 LC1D25.D38 LR97D038M7 LR97D038F7 LR97D038B LR97D038E
0,5.60
Relay type
Relay setting range References 200. 100. VAC/DC VAC/DC
Electronic over current relays
TeSys LT47 with manual reset 0,5.6 LT4706M7S LT47D06F7S LT47D06BS LT47D06ES 3.30 LT47D30M7S LT47D30F7S LT47D30BS LT47D30ES 5.60 LT4760M7S LT4760F7S LT4760BS LT4760ES
Relay type
Relay setting range References 200. 100. VAC/DC VAC/DC Accessories please consult your Schneider Electric agency.
Electronic over current relays
TeSys LT47 with automatic reset 0,5.6 3.30 LT4706M7A LT47D06F7A LT47D06BA LT47D06EA LT47D30M7A LT47D30F7A LT47D30BA LT47D30EA 5.60 LT4760M7A LT4760F7A LT4760BA LT4760EA
Other versions: please consult your Schneider Electric agency.
5/29
TeSys
Motor management system
Controllers
Type fieldbus Modbus
Current range 0.4.8 1.35.27 5.100 LTMR08MBD LTMR27MBD LTMR100MBD 100.240 LTMR08MFM LTMR27MFM LTMR100MFM
Profibus
LTMR08PBD LTMR27PBD LTMR100PBD 100.240 LTMR08PFM LTMR27PFM LTMR100PFM
Supply voltage References
Type fieldbus
Supply voltage References Current range 0.4.8 1.35.27 5.100
CANopen
LTMR08CBD LTMR27CBD LTMR100CBD 100.240 LTMR08CFM LTMR27CFM LTMR100CFM
DeviceNet
LTMR08DBD LTMR27DBD LTMR100DBD 100.240 LTMR08DFM LTMR27DFM LTMR100DFM
Extension module
Type module
Inputs voltage References
Extension additional inputs voltage measuring
LTMEV40BD 100.240 LTMEV40FM
Ethernet external port Modbus Modbus TCP/IP
TCSEQM113M13M
Operator dialogue terminal software
Type terminal
Description Supply voltage References
Compact display
lines characters XBTN410
Configuration software
Windows 2000, XBTL1000
Other versions: please consult your Schneider Electric agency.
5/30
TeSys
Motor management system
Current transformers
Type transformer
Operational current References primary secondary
External
LT6CT1001 LT6CT2001 LT6CT4001 LT6CT8001
Earth fault toroids
Type toroid
Maximum current Internal diameter References
Closed
TA30 PA50 IA80 MA120 SA200 GA300
Split
thermistor probe
Type probe
Operating temperature References
Triple
90°C 110°C 120°C DA1TT120 130°C 140°C 150°C 160°C 170°C
DA1TT090 DA1TT110
DA1TT130 DA1TT140 DA1TT150 DA1TT160 DA1TT170
Accessories
Type accessory
Length cable References
Connecting cable
Controller Extension module 0.04 LTMCC004 LU9R03 LU9R10
Type accessory
Length cable References other connection accessories, www.schneider-electric.com
Connecting cable
Controller Display XBTZ938
Connection
serial port VW3A8106
Other versions: please consult your Schneider Electric agency.
TeSys
LT3,
Electronic protection relays with thermistor probes
0.800
with contactor Motor current Basic reference, completed
LC1-D LC1-F limit LT3-S
LC1-D LC1-F
3-pole multifunction protection relays 3-pole multifunction protection relays
Operational current
0.2.1. LT6-P0M005FM
5.25 LT6-P0M025FM
Protection units with automatic reset with thermistor short-circuit detection
without fault memory
Connection cage connectors 50/60
Voltage 115/230 24/48 24.230
Output contact
Reference LT3-SE00F LT3-SE00M LT3-SE00F LT3-SA00M LT3-SA00ED LT3-SA00MW
front panel: fault voltage signalling indicator 50/60 50/60
with fault memory
front panel: fault voltage signalling indicator, Test Reset button 50/60 24/48 115/230 50/60 24/48 24.230 LT3-SM00V LT3-SM00E LT3-SM00M LT3-SM00ED LT3-SM00MW
Accessories
thermistor probes relays Normal operating temperature (NOT) Integrated triple probes Normal operating temperature (NOT) DA1-TT090 DA1-TT110 DA1-TT120 DA1-TT130 DA1-TT140 DA1-TT150 DA1-TT160 DA1-TT170 DA1-TS060 DA1-TS070 DA1-TS080 DA1-TS090 DA1-TS100 LA9-P621 LT6-CT1001 Comprising diskettes, connection cable with SUB-D 9-pin connectors (female-female) LT6-CT4001 LT6-CT8001 Diskette
Surface probes Configuration software relays Languages: English, French, German, Italian, Spanish with relay sizes Operational current LA9-P620 primary secondary Current transformers relays
Other versions: please consult your Schneider Electric agency.
Vario
Protection components 12.175
Switch disconnectors
5/L3
2/T1
Type
Colour handle Front plate Front plate dimensions (mm) Fixing Degree protection Rated operational voltage (Ue) Thermal current open (Ith)
6/T3
Mini-Vario standard applications
Mounting door Yellow 22.5 VCDN12 VCDN20 VBDN12 VBDN20 Black Black Backplate mounting enclosure Yellow 22.5 VCCDN12 VCCDN20
5/L3
Vario high performance applications
Mounting door Backplate mounting enclosure screws VBD02 VBD01 VBD0 VBD1 VBD2 VCF02 VCF01 VCF0 VCF1 VCF2 VCF3 VCF4 VBF02 VBF01 VBF0 VBF1 VBF2 VBF3 VBF4 screws VCF5 VCF6 22,5 screws VCCD02 VCCD01 VCCD0 VCCD1 VCCD2 VCCF02 VCCF01 VCCF0 VCCF1 VCCF2 VCCF3 VCCF4 screws VCCF5 VCCF6 Yellow Black Black Yellow Black Black Yellow 22,5 VCD02 VCD01 VCD0 VCD1 VCD2
Type
Colour handle Front plate Front plate dimensions (mm) Fixing Degree protection Rated operational voltage (Ue) Thermal current open (Ith)
6/T3
Add-on modules
Main pole modules Rating References Neutral pole module with early make late break contacts Rating References Earthing module References Auxiliary contact block modules Contact types References VZN05 VZN06 VZ20 VZN14 VZ14 VZ15 VZ16 12.20 VZN11 12.40 VZ11 VZ12 VZ13 VZN12 VZN20 VZ02 VZ01
mini-Vario
Vario
Other versions: please consult your Schneider Electric agency.
5/33
TeSys
GV2,
Combination motor starters
0.06.15
D.O.L. starters
with circuit-breaker with fuse protection Type Fuse carrier plate-mounted contactor GV2-DP LC4-D
Level service Power Type components Basic reference, completed
Coordination:
Type incorporated circuit-breaker GV2-ME GV2-DM Combination automatic motor starter with overload protection
Starters GV2-ME
Non-reversing Standard power ratings 3-phase motors Setting range thermal trips 1.1.6 0.37 0.55 0.75 9.14 GV2-ME16 LC1-K12 6.10 GV2-ME14 LC1-K09 4.6.3 GV2-ME10 LC1-K06 2.5.4 GV2-ME08 LC1-K06 1.6.2.5 33.5 GV2-ME07 LC1-K06 Fixed magnetic tripping current Irth 22.5 GV2-ME06 LC1-K06 customer assembly Motor circuit-breaker Contactor Factory assembled Basic reference, completed with code indicating control circuit voltage Reversing
50/60 category AC-3 (kW) 400/415 0.37 0.55 0.75 0.37 0.55 0.75
Standard control circuit voltages (for other voltages, please consult your Regional Sales Office) Volts 50.400 220/230 230/240 380/400
consumption coil (1.5 wide range (0.7.1.3 with integral suppression device standard.
Other versions: please consult your Schneider Electric agency.
5/34
D.O.L. starters GV2-DM GV2-DP
Non-reversing Standard power ratings 3-phase motors 50/60 category AC-3 (kW) 400/415 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.37 0.55 0.75 18.5 13.18 17.23 20.25 24.32 9.14 6.10 4.6.3 2.5.4 1.6.2.5 33.5 GV2-ME07 GV2-P07 GV2-ME08 GV2-P08 GV2-ME10 GV2-P10 GV2-ME14 GV2-P14 GV2-ME16 GV2-P16 GV2-ME20 GV2-P20 GV2-ME21 GV2-P21 GV2-ME22 GV2-P22 GV2-ME32 GV2-P32 1.1.6 22.5 0.63.1 0.40.0.63 0.16.0.25 0.25.0.40 Setting range thermal trips Fixed magnetic tripping current Irth GV2-ME02 GV2-P02 GV2-ME03 GV2-P03 GV2-ME04 GV2-P04 GV2-ME05 GV2-P05 GV2-ME06 GV2-P06 customer assembly Motor circuit-breaker Contactor Factory assembled Basic reference, completed with code indicating control circuit voltage Reversing
Standard control circuit voltages (for other voltages, please consult your Regional Sales Office) Volts 50.400
consumption coil (1.5 wide range (0.7.1.3 with integral suppression device standard.
Other versions: please consult your Schneider Electric agency.
5/35
TeSys
Starter-controller 3-phase motors
STANDARD motor starter
Function characteristics, LUB. LUCA.
Maximum motor power
400/415 Thermal overload protection against: short-circuit, overcurrent, phase failure imbalance, insulation breaks (equipment only). Manual reset following thermal fault. 0.09 0.25 LUB12 LUB12 LUB12 LUB12 LUB32 LUB3
Power base
Non-reversing Reversing LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp
Standard control unit
Class LUCA6Xpp LUCA1Xpp LUCA05pp LUCA12pp LUCA18pp LUCA32pp 0.15.0.6 0.35.1.4 1.25.5 3.12 4.5.18 8.32 Setting range
ADVANCED motor starter
Function characteristics, LUB. LUCA. Maximum Power base motor power Non-reversing Reversing
400/415 LUB12 LUB12 LUB12 LUB12 LUB32 LUB32 LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp 0.09 0.25
Advanced control unit
Class LUCB6Xpp LUCB1Xpp LUCB05pp LUCB12pp LUCB18pp LUCB32pp Class LUCD6Xpp LUCD1Xpp LUCD05pp LUCD12pp LUCD18pp LUCD32pp 0.15.0.6 0.35.1.4 1.25.5 3.12 4.5.18 8.32 Setting range
Thermal overload protection against: short-circuit, overcurrent, phase failure imbalance, insulation breaks (equipment only). Manual reset following thermal fault. Thermal overload test function.
single-phase-motors, replace LUCBpppp LUCCpppp.
MULTIFUNCTION motor starter
Function characteristics, LUB. LUCA. Maximum motor power
400/415 Thermal overload protection against: 0.09 0.25 LUB12 LUB12 LUB12 LUB12 LUB32 LUB3
Power base
Non-reversing Reversing LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp
Multifunction control unit
Class LUCM6XBL LUCM1XBL LUCM05BL LUCM12BL LUCM18BL LUCM32BL Setting range 0.15.0.6 0.35.1.4 1.25.5 3.12 4.5.18 8.32
short-circuit, overcurrent, phase failure imbalance, insulation breaks (equipment only). Manual, automatic remote reset, Thermal overload test function, Overtorque no-load running, alarm,
Motor operation log, Motor parameters display LUCM., HMI, Integrated Modbus communication. Complete references power bases according following table. Complete references control units according following table. Example: LU2B12 Example: LUCA/B/D/M6X
Standard control circuit voltages 48.72 110.240 110.220
Other versions: please consult your Schneider Electric agency.
5/36
TeSys
Starter-controller 3-phase motors
Function modules
Type optional function
Compatible with LUCA Compatible with LUCL Compatible with LUCB, LUCD Compatible with LUCM Output signal Reset References
Thermal overload alarm
LUFW10
Thermal fault signalling
Manual LUFDH11 Automatic remote LUFDA01 LUFDA10
Motor load indication
4.20 LUFV
Communication modules
Type communication
Only compatible with control units LUCA.BL, LUCB.BL, LUCD.BL, LUCM.BL Transfer speed Number slaves Pre-wired coil connection Connecting cable References Network Interface Module. 19.2 Kbps Modbus master LU9BN11C, LU9MRC Dpg. 9,6.12 Mbps Dpg. Network LU9BN11L, LU9MRL LU9RDDpp LUFC033 LULC15 LULC07 LULC08 Interface Module module LU9BN11L, LU9MRL TSXPBSCApp Mbps module LU9BN11L, LU9MRL TSXCANCpp 125.500 Kbaud Kbps DeviceNet module LU9BN11L, LU9MRL DeviceNet standard LULC09 ASILUFC51 LUFC00 master LU9BN11C, LU9MRC XZCG0142 TSXCDPppp splitter LU9Rxx Profibus CANopen AS-Interface LU9GC0
Modbus
Advantys
Profibus CANopen
DeviceNet
AS-Interface Parallel wiring
LU9RCDpp,
Information carried Modbus, Advantys CANopen
Type control unit Start Stop commands Starter status (ready, running, fault) Thermal alarm Remote reset Indication motor load Signalling fault differentiation Alarms (overcurrent, Remote programming monitoring functions "Log" function Monitoring function LUCAppBL LUCBppBL, LUCDppBL LUCMppBL
Contact blocks
Type contact block
Signalling contacts auxiliary contacts module References Screw clamp terminals Without connections fault position control handle
Add-on
(95-96) (17-18) LUA1C11 LUA1C110 (97-98) (17-18) LUA1C20 LUA1C200
Auxiliary
(33-34) (43-44) LUFN20 (31-32) (43-44) LUFN11 (31-32) (41-42) LUFN02
Other versions: please consult your Schneider Electric agency.
5/37
TeSys
LUTeSys GV3L Circuit-breakers
Controller 3-phase motors
MULTIFUNCTION protection
TeSys LC1D Contactor
Control base with contactors
TeSys (LC1D.) LUTM10BL
Multifunction control unit
TeSys (LC1F.) LUTM20BL Class LUCMT1BL
Function characteristics
Thermal overload protection against: short-circuit, overcurrent, phase failure imbalance, insulation breaks (equipmemt only). Manual, automatic remote reset,
Thermal overload test function, Overtorque no-load running, alarm, Motor operation log, Motor parameters display LUCM., HMI, Integrated Modbus communication.
ADVANCED protection
Function characteristics Control base with contactors
TeSys (LC1D.) Thermal overload protection against: short-circuit, overcurrent, phase failure imbalance, insulation breaks (equipmemt only). LUTM10BL TeSys (LC1F.) LUTM20BL
Advanced control unit
Class LUCBT1BL Class LUCDT1BL
Manual reset following thermal fault. Thermal overload test function.
Current transformers
Type transformer
Supply voltage Operating current References Primary Secondary
LUTC0301 LUTC0501 LUTC01001 LUTC02001 LUTC04001 LUTC05001
Above TeSys controller provides motor starter management system solution identical that provided TeSys starter-controller.
Used conjunction with short-circuit protection device contactor, provides motor starter whose functions same those TeSys starter-controller and, particular, provides following functions: overload protection, motor starter control application monitoring. comprises control unit, whose adjustment range compatible with secondary current transformers, control base that also enables fitting function module communication module. requires external power supply.
Other versions: please consult your Schneider Electric agency.
5/38
TeSys
LU
Controller 3-phase motors
Function modules
Type optional function
Compatible with LUCA Compatible with LUCL Compatible with LUCB, LUCD Compatible with LUCM Output signal Reset References
Thermal overload alarm
LUFW10
Motor load indication
4.20 LUFV
Communication modules
Type communication
Only compatible with control units LUCA.BL, LUCB.BL, LUCD.BL, LUCM.BL Transfer speed Number slaves Pre-wired coil connection Connecting cable References 19.2 Kbps Modbus master LU9BN11C, LU9MRC LU9RDDpp LUFC033 LULC15 LULC08 Dpg. Dpg. Network Interface Module LU9BN11L, LU9MRL LU9RCDpp, Mbps CANopen module LU9BN11L, LU9MRL TSXCANCpp 125.500 Kbaud DeviceNet module LU9BN11L, LU9MRL DeviceNet standard LULC09 LUFC00 TSXCDPppp LU9GC02 splitter LU9Rxx
Modbus
Advantys
CANopen
DeviceNet
Parallele wiring
Information carried Modbus, Advantys CANopen
Type control unit Start Stop commands Starter status (ready, running, fault) Thermal alarm Remote reset Indication motor load Signalling fault differentiation Alarms (overcurrent, Remote programming monitoring functions "Log" function Monitoring function LUCBT1BL, LUCDT1BL LUCMT1BL
Other versions: please consult your Schneider Electric agency.
5/39
TeSys
Enclosed motor starters
0.06.132
Starters
D.O.L.
0.06.37 GV2-ME GV3-PC GV3-CE LE2-K LE2-D 0.55.30 GV2-LC GV-NGC 0.37.5.5 LE1-GVME 0.25.45 LE1-M LE1-D
standard
Standard power ratings 3-phase motors category 400/415 Starters Isolating device manual auto switch-disconnector-fuse circuit-breaker fuse carrier Protection Communication Basic reference reversing short-circuit overload
4.37 VCFN
Reversing
Other versions: please consult your Schneider Electric agency.
5/40
safety applications AS-i
stage
7.5.75 LE6-D LE3-D
standard star-delta 5.5.132 LE3-K LE3-D LE3-F
2.2.45 LE4-K LE4-D LE8-K LE8-D LE2-D
0.06.11 GV2-ME
0.06.9 LG1-K LG1-D
0.06.9 LG7-K LG7-D LJ7-K LG8-K LJ8-K
0.06.5.5 LF1-M LF1-P LF7-P LF2-M LF2-P LF8-P
Other versions: please consult your Schneider Electric agency.
TeSys
Quickfit
Installation system
Presentation
TeSys Quickfit modular system which standardises simplifies implementation motor starters with pre-wired control power circuits.
Installation motor starter becomes quick, simple, safe flexible. addition, this system: enables motor starter customised later date, reduces maintenance time optimises panel space reducing number terminals intermediate interfaces amount ducting.
motor starters concerned those created combining: circuit-breakers, with operating limit maximum current ambient temperature with TeSys (LC1) contactors. This offer comprises components pre-wiring
power part, control part.
Components pre-wiring power part
power comprising, each starter, plate mounting contactor circuit-breaker, power connection modules, power splitter starters,
upstream terminal block power supply mm2), downstream terminal block connecting motor power supply cables earth cables mm2).
Components pre-wiring control part
control circuit connection module that mounts directly contactor circuit-breaker
each starter. This module integrates status control information this particular motor starter. parallel wiring module enabling grouping information relating each motor starter: intended centralised applications. information transmitted Advantys Telefast pre-wired system. STB, intended decentralised automation architectures. This module integrated Advantys configuration connection fieldbus.
9.25 power pre-wiring components
Type
Maximum c.s.a. connection
Terminal block Upstream
Splitter boxes supply LAD3B
Downstream
Motor cables LAD33
power splitter Extension LAD32p
LAD322 LAD324
Number starters Reference
Type Connection D.O.L. starter
mounting plate LAD311 GV2ME power connection modules LAD341 Reference reversing starter order connection kits LAD25Other versions: please consult your Schneider Electric agency.
Mounting plate Power connection contactor module
motor starter LAD311 LAD34
Composition
LAD25
Control-command pre-wiring components
Type
TeSys coil voltage Type coil control relay Type motor starter Reference
Connection module
12.250 5.130 Electronic Direct LAD9AP31 Reversing LAD9AP32 Without relay Direct LAD9AP3D1 Reversing LAD9AP3D
Type
PLC/motor starter side connectors Reference
parallel wiring module Splitter
HE10/8 RJ45 LU9G0
Advantys parallel interface module
RJ45 STBEPI2145
Accessories
Type
Connectors Gauge c.s.a. Reference
Connecting cables From splitter LU9G02
RJ45 LU9R03 LU9R10 LU9R30 HE10 0.324 TSXCDP053 TSXCDP103 TSXCDP203 TSXCDP303 TSXCDP503 0.080 ABFH20H100 ABFH20H200 ABFH20H300 Bare wires HE10 0.324 TSXCDP301 TSXCDP30
From connection module LAD9AP3p splitter LU9G02 module STBEPI2145
Connecting cable Self-stripping
Between communication module APP1Cp splitter LU9GG02 APP2AH40H060
Type
Reference
Connectors Spring terminals
External contact, auxiliary power supply APE1PRE21 APE1PAD10
Other versions: please consult your Schneider Electric agency.
5/43
Components
Sodium vapour lamps
pressure
Lighting applications (AC5)
corrected 31.2
high pressure
With parallel compensation 1000 12.4 1002 1352 1982 0.84 1014 1488 1000 LC1K09 D09, D32, D50, D80, D115, D150 F185 F225 F265 F330 F400 F500 F630, F800 LC1K09 D09, D32, D50, D80, D115, D150 F185 F225 F265 F330 F400 F500 F600, F800
Max. number lamps accordint (W), contactor
Max. number lamps accordint (W), contactor
Metal iodine vapour lamps
Max. number lamps accordint (W), contactor
1000
2000
1000
2000 11.2 LC1K09 D09, D32, D50, D80, D115, D150 F185 F225 F265 F330 F400 F500 F630, F800
Other versions: please consult your Schneider Electric agency.
5/44
Incandescent halogen lamps
Max. number lamps accordint (W), contactor 0.27 1006 1274 1718 2328 2776 0.34 1010 1364 1850 2204 0.45 1030 1396 1666 0.68 1102 0.91 1.40 2.30 3.40 1000 4.60 LC1K09 D09, D32, D50, D80, D115 D150 F185 F225 F265 F330 F400 F500 F600 F800
Fluorescent lamps with starter single fitting
Non-corrected Max. number lamps accordint (W), contactor 0.39 1190 twin fitting
With parallel correction 0.70 2x65 2x10 2x14 2x18 2x26 2x32 2x40 2x58 2x118 2x142 2x154 2x178 2x202 2x256 2x346 2x468 0.80 2x80 2x12 2x14 2x20 2x26 2x34 2x48 2x96 2x116 2x126 2x146 2x166 2x210 2x282 2x384 2x110 2x10 2x14 2x18 2x24 2x36 2x72 2x86 2x94 2x108 2x124 2x156 2x210 2x286 0.17 1128 1224 1412 1600 2024 2728 3700 2x20 2x36 2x60 2x80 2x100 2x134 2x168 2x214 2x306 2x614 2x738 2x800 2x922 0.26 1046 1322 1724 2418 2x40 2x20 2x32 2x42 2x54 2x72 2x90 2x116 2x166 2x332 2x400 2x432 2x500 0.42 1104 1498 2x65 2x12 2x20 2x26 2x32 2x44 2x56 2x70 2x102 2x204 2x246 2x266 2x308 2x348 2x440 2x594 0.52 1210 2x80 2x10 2x16 2x20 2x26 2x36 2x44 2x58 2x82 2x166 2x200 2x216 2x250 2x282 2x358 2x482 2x654 0.72 2x110 LC1K09 D09, D32, D50, D80, D115, D150 F185 F225 F265 F330 F400 F500 F630, F800 2x12 2x16 2x20 2x26 2x32 2x42 2x60 2x122 2x148 2x160 2x184 2x208 2x264 2x356 2x484 LC1K09 D09, D32, D50, D80, D115, D150 F185 F225 F265 F330 F400 F500 F630, F800 0.45 1030 1398 2x40 2x11 2x18 2x24 2x30 2x42 2x52 2x68 2x96 2x194 2x234 2x254 2x292 2x332 2x420
Max. number lamps accordint (W), contactor
2x20 2x0.22 2x21 2x36 2x46 2x58 2x78 2x100 2x126 2x180 2x360 2x436 2x472 2x544 2x618 2x78
2x0.41 2x0.67 2x0.82 2x1.
2x0.13 2x0.24 2x0.39 2x0.48 2x0.65
2x1046 2x566 2x1322 2x716 2x1784 2x966
2x1054 2x566 2x1430 2x766
2x2418 2x1310 2x806
Other versions: please consult your Schneider Electric agency.
5/45
Components
Capacitor switching
0.1000 kVAR
On-load capacitor switching
bar-mounted contactors, a.c. control circuit
Without damping resistor Rated operational voltage Number poles Max. operational current 1300 80x2 160x2 240x2 80x3 160x3 240x3 1500 poles series poles series 2000 poles series poles series poles series 280x2 240x2 60x2 125x2 190x2 60x3 125x3 190x3 220x2 190x2 Basic reference, completed
With damping resistor Number poles Max.operational current staggered pole Basic reference, completed
staggered poles
240x
190x
staggered poles staggered poles staggered poles
3000
Standard control circuit voltages
supply Volts (coil LX1)
Other versions: please consult your Schneider Electric agency.
5/46
Maximum operational power contactors
standard contactors
Operational power 50/60 kVAR
special contactors
kVAR 8350 1100 kVAR 1300 kVAR kVAR 1000 kVAR 1000
Peak current
Contactor size
1600 1900 2160 2160 3040 3040 3100 3300 3500 4000 5000 6500 8000 10000 12000 14200 25000 25000 25000 25000 LC1-D09, LC1-D18 LC1-D25 LC1-D32, LC1-D40A LC1-D50A LC1-D65A LC1-D80, LC1-D115 LC1-D150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 LC1-F800 LC1-BL LC1-BM LC1-BP LC1-BR
Operational power 50/60 kVAR kVAR 12.5 16.7 33.3 kVAR Instantaneous auxiliary contacts Tightening torque cable Basic reference, completed
Standard control circuit voltages
supply Volts 50/60 (coil LX1)
Other versions: please consult your Schneider Electric agency.
5/47
Components
Heating applications changeover contactor pairs
0.2750
Maximum operational current (device open air)
Contactors
3-pole 4-pole
LC1-/LP1- LC1-/LP1- LC1K09 K09004
LC1DT20
LC1D12 DT25 DT20
LC1D18 DT32 DT25
LC1D25 DT40 DT32
LC1D32 DT40
LC1D38
LC1D40A DT60A
LC2- changeover contactor pairs, factory assembled Operational current AC-1, according ambient temperature Maximum operational power 220/230 380/400
K12004
660/690
Increase operational current parallel connection poles Apply following coefficients currents powers above; these coefficients take into account often unbalanced distribution current between poles: poles parallel poles parallel 2.25 poles parallel
Connection accessories heating applications
Paralleling links for:
TeSys
Reference poles poles poles with screw clamp terminals with screw clamp terminals D09.D38 DT20 DT25 (4P) DT32.DT40 (4P) D40A.D65A LA9-E01 LA9-E02 LA9-D2561 LA9-D1261 LAD-D96061 LAD-9P32 LA9-D80961 LAD-9P3 LAD-9P33 LA9-D80962 LA9-D1263 LAD-9P33 LA9-D80963 LA9-FF602 LA9-FG602 LA9-FH602 LA9-FK602 LA9-FL60
TeSys
poles
D09.D38 D40A.D65A
poles
DT20.DT25 D40A.D65A
TeSys
LC1-F1154 LC1-F1504, F1854 LC1-F2254, F2654, F3304, F4004 LC1-F5004 LC1-F6304
Link that split, allowing parallel connection poles
Other versions: please consult your Schneider Electric agency.
5/48
LC1D50A
LC1D65A DT80A
LC1D80 D80004
LC1D115
LC1F185
LC1F225 F2254
LC1F265 F2654
LC1F330
LC1F400
LC1F500
LC1F630
LC1F780
LC1F800
LC1BL
LC1BM
LC1BP
LC1BR
D115004 F1854
1000 1000
1600 1350 1100 1000 1050 1200 1650
1000 1000
1250 1100 1100
2000 1750 1500 1200 1250 1400 1500 1900
2750 2400 2000 1000 1100 1600 1700 2000 2100 2700
Other versions: please consult your Schneider Electric agency.
5/49
Components
Accessories changeover contactor pairs
0.2750
Mounting accessories changeover contactor pairs
(for customer assembly) Contactor type contactors, vertically mounted
4-pole changeover pairs with locking device components
power connections
Mechanical interlock
Contactor type
power connections
Mechanical interlock
LC1-B identical contactors, horizontally mounted
EZ2-LB060
with electrical interlocking contactors
LC1-DT20.DT40 LP1-D80004
without electrical interlocking
LAD-T9R1V LA9-D8070 LAD-T9R1 LA9-D8070 LA9-D80978 LA9-D8002 LC1-D115004 LC1-DT40 DT60 LA9-D11570 LAD-T9R2 LA9-D1150
mechanical interlock with integral electrical interlocking
LC1-DT20.DT3
LP1-D80004
4-pole changeover pairs
contactors identical rating, horizontally mounted LC1-F1154 LC1-F1854 LC1-F2654 LA9-FF977 LA9-FG977 LA9-FH977 LA9-FJ977 LA9-FL977 LA9-D1157(3)
LA9-FF970 LA9-FG970 LA9-FJ970 LA9-FJ970 LA9-FL970 LA9-D1150
LC1-F1504 LC1-F2254 LC1-F3304 LC1-F5004
LA9-F15077 LA9-F22577 LA9-FJ977 LA9-FK977
LA9-FF970 LA9-FG970 LA9-FJ970 LA9-FJ970
LC1-F4004 LC1-F6304 LC1-D115 D150
3-pole changeover pairs with electrical interlocking
reversers assembled using contactors, vertically mounted
4-pole changeover pairs using contactors identical rating 4-pole changeover pairs using contactors different rating
bottom LC1-F1154 F1505 LC1-F1854 LC1-F2254 LC1-F2654 F3304 LC1-F4004 LA9-FF4F LA9-FG4G LA9-FG4G LA9-FH4H LA9-FJ4J LA9-FK4K LA9-FL4L LA9-FX971 LC1-F185 F1854 LC1-F225 F2254 LC1-F115 F1154 LC1-F150 F1504
LC1-F185 F1854 LC1-F225 F2254 LC1-F265 F2654 LC1-F300 F3304 LC1-F400 F4004 LC1-F500 F5004 LC1-F630, F6304 F800 LC1-F265 F2654 LC1-F330 F3304 LC1-F400 F4004 LC1-F500 F5004 LA9-FG4F LA9-FG4F LA9-FH4F LA9-FH4F LA9-FJ4F LA9-FK4F LA9-FL4F LA9-FH4G LA9-FH4G LA9-FJ4G LA9-FK4G LA9-FL4G LA9-FJ4H LA9-FK4H LA9-FL4H LA9-FK4J LA9-FL4J LA9-FL4K
LC1-F5004 LC1-F6304 LC1-F7804
LC1-F630, F6304 F800 LC1-F265 F2654 LC1-F330 F3304 LC1-F400 F4004 LC1-F400 F4004 LC1-F500 F5004 LC1-F630, F6304 F800 LC1-F500 F5004 LC1-F630, F6304 F800 LC1-F630, F6304 F800
LC1-F500 F5004
Including mechanical interlock, Order separately auxiliary contact blocks obtain electrical interlocking between contactors, Power connections made customer. Double mechanical interlock mechanism with interlock connecting rods power connecting links.
Other versions: please consult your Schneider Electric agency.
5/50
TeSys
Notes
Other versions: please consult your Schneider Electric agency.

Other recent searches


TPA6045A4C - TPA6045A4C   TPA6045A4C Datasheet
TLE4209G - TLE4209G   TLE4209G Datasheet
SPWA033 - SPWA033   SPWA033 Datasheet
NDS332P - NDS332P   NDS332P Datasheet
MC8323 - MC8323   MC8323 Datasheet
DTC114GUA - DTC114GUA   DTC114GUA Datasheet
DTC114GKA - DTC114GKA   DTC114GKA Datasheet
DTC114GSA - DTC114GSA   DTC114GSA Datasheet
AN705 - AN705   AN705 Datasheet
Si9910 - Si9910   Si9910 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheets.org.uk