Magnetic latching contactors GCR1-F series magnetic latching contactor


  

Download PDF



Top Searches for this datasheet



Motor Control Device
Magnetic latching contactors GCR1-F series magnetic latching contactors
Magnetic latching contactors both block mounted types fitted with special electromagnet which enables them remain "On" position when coil longer energised.
Applications
special properties magnetic latching contactors make them suitable large number applications.
Properties
Retention sequence memory automatic control equipment event loss control voltage. Energy saving, since source supply coil does need supply current when contactor latched closed state. Change state from "Closed" "Open" current signal through coil. Unaffected mains interference. Utilisation contactors beyond their breaking capacity, operations performed off-load. Contactors silent latched position.
Applications
Refineries, power stations, excitation circuits. Contactors remaining closed state long periods. Examples: refineries, power supplies, voltage distribution. Selective opening control. unwanted opening closing main power poles. Current carrying voltages 1000 Volts.
Operation electromagnet GCR1-F block contactors
GCR1-F magnetic latching contactors fitted with double coil with terminals comprising latching winding unlatching winding. windings have common point which necessitate special wiring precautions when latching supply separate from unlatching supply. power supplies a.c. d.c. d.c. operation, polarities indicated must complied with. Operating precautions: windings must supplied simultaneously, winding must supplied continuously, supply coils must pulsed contacts. Manual opening: control voltage present, contactor unlatched manually.
Selection guide utilisation category AC-3
Rated operational current AC-3 440V 500V 660V 690V Rated operational power (standard motor power ratings) 220V 240V 380V 400V 415V 440V 500V 660V 690V GCR1-F1503 GCR1-F1504 Reference
GCR1-F1853 GCR1-F1854 GCR1-F2653 GCR1-F2654 GCR1-F4003 GCR1-F4004 GCR1-F5003 GCR1-F5004
GCR1-F6303 GCR1-F6304
Greegoo Electric 11.2007
http://www.greegoo.com
Motor Control Device
Magnetic latching contactors GCR2-F series reversing magnetic latching contactors
Rated operational current AC-3 440V 500V 660V 690V
Rated operational power (standard motor power ratings) 220V 240V 380V 400V 415V 440V 500V 660V 690V
Reference
GCR2-F1503 GCR2-F1504
GCR2-F1853 GCR2-F1854 GCR2-F2653 GCR2-F2654 GCR2-F4003 GCR2-F4004 GCR2-F5003 GCR2-F5004
GCR2-F6303 GCR2-F6304
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic latching contactors Coils magnetic latching contaetors GCR1-F
Standard coils
Usual voltages 50.400Hz 50Hz, 60Hz
220/230 380/400
Resistance winding Latching Reference Voltage code Unlatching Weigth
contactors GCR1 F150 1.98 9.35 11.61 23.50 37.55 45.16 114.10 139.50 230.8 1453 1788 4098 5139 6544 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 FF005 FF006 FF007 FF020 FF008 FF009 FF010 FF011 0.440 0.440 0.440 0.440 0.440 0.440 0.440 0.440
contactors GCR1 F185 1.42 6.92 8.45 21.30 220/230 26.27 32.95 380/400 82.29 102.30 contactors GCR1 F265 220/230 380/400 1.34 6.90 8.56 20.20 25.77 33.03 78.39 102.9
1339 1676 3169 4729 4729
GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0
FG005 FG006 FG007 FG020 FG008 FG009 FG010 FG011
0.560 0.560 0.560 0.560 0.560 0.560 0.560 0.560
183.4 1031 1325 2654 4090 5002
GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0
FH005 FH006 FH007 FH020 FH008 FH009 FH010 FH011
0.780 0.780 0.780 0.780 0.780 0.780 0.780 0.780
contactors GCR1 F400 1.32 8.09 9.79 24.40 220/230 30.14 37.02 380/400 94.80 121.10 contactors GCR1 F500 220/230 380/400 1.57 7.53 9.56 23.60 28.81 35.67 89.56 112.06
90.5 1027 2643 3309 4074 9380
GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0
FJ005 FJ006 FJ007 FJ020 FJ008 FJ009 FJ010 FJ011
1.120 1.120 1.120 1.120 1.120 1.120 1.120 1.120
1159 2981 3733 4595
GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0
FK005 FK006 FK007 FK020 FK008 FK009 FK010 FK011
1.220 1.220 1.220 1.220 1.220 1.220 1.220 1.220
Greegoo Electric 11.2007
http://www.greegoo.com
contactors GCR1 F630 0.87 5.20 6.45 20.20 220/230 25.36 25.36 380/400 60.95 77.97
1423 1830 2961 4603 5658
GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0 GLX0
FL005 FL006 FL007 FL020 FL008 FL009 FL010 FL011
1.460 1.460 1.460 1.460 1.460 1.460 1.460 1.460
Motor Control Device
Magnetic latching contactors Coils contactors GCR1-F
Standard coils
Coils wiht windings with common point, allowing separte power sources latching unlatching
Usual voltages 50.400Hz 50Hz, 60Hz
Resistance winding Latching
Reference
Voltage code
Unlatching
Weigth
contactors GCR1 F150 29.5 39.5 GLX0 FF224 0.440
contactors GCR1 F185 26.5 GLX0 FG224 0.560
contactors GCR1 F265 contactors GCR1 F400
29.5
GLX0 FH224
0.780
GLX0 FJ224
1.120
contactors GCR1 F500 GLX0 FK224 1.220
contactors GCR1 F630
GLX0 FL224
1.460
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors GLC1-F series magnetic contactors
3/4-pole contactors
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 230V 400V (kW) (kW) (kW) (kW) (kW)
3-pole contactors motor control, Utilisation category AC-3 Control circuit a.c. d.c. References
660V 690V (kW)
Rated operational current AC-3 440V
Basic reference. Screw fixing, cabling
GLC1-F1153 GLC1-F1154 GLC1-F1503 GLC1-F1504 GLC1-F1853 GLC1-F1854 GLC1-F2253 GLC1-F2254 GLC1-F2653 GLC1-F2654 GLC1-F3303 GLC1-F3304 GLC1-F4003 GLC1-F4004 GLC1-F5003 GLC1-F5004 GLC1-F6303 GLC1-F6304 GLC1-F7803 GLC1-F7804
Greegoo Electric 11.2007
http://www.greegoo.com
Motor Control Device
Magnetic contactors GLC2-F series reversing magnetic contactors
Standard power ratings 3-phase motors 50/60 category AC-3 440V 500V 220V 380V 415V (kW) (kW) 230V 400V (kW) (kW) (kW)
660V 690V (kW)
Rated operational current AC-3 440V
Basic reference. Screw fixing, cabling
GLC2-F1153 GLC2-F1154 GLC2-F1503 GLC2-F1504 GLC2-F1853 GLC2-F1854 GLC2-F2253 GLC2-F2254 GLC2-F2653 GLC2-F2654 GLC2-F3303 GLC2-F3304 GLC2-F4003 GLC2-F4004 GLC2-F5003 GLC2-F5004 GLC2-F6303 GLC2-F6304 GLC2-F7803 GLC2-F7804
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magneti contactors GLC3-F series star delta starter
Standard power ratings 3-phase motors 50/60 category AC-3 220V (kW)
220V (hp)
380V (kW)
380V (hp)
415V 440V (kW)
415V 440V (hp)
Rated operational current AC-3 440V
Rated insulation voltage
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Thermal current Ithe
Reference
1000 1000
GLC3-F115 GLC3-F150 GLC3-F185 GLC3-F225 GLC3-F265 GLC3-F330 GLC3-F400 GLC3-F500 GLC3-F630 GLC3-F800
Greegoo Electric 11.2007
http://www.greegoo.com
Motor Control Device
Magnetic contactors
Contactors type GLC1-F Coils GLC1-F115 F225, a.c. supply 50/60 References
Control circuit voltage 50Hz 60Hz
Average resistance
Inductance colsed circuit
Voltage code
Reference
Weight (kg)
contactors GLC1-F115 GLC1-F150
Specifications
Average consumption inrush sealed 0.32. 2400. Operating cycles/hour 220/230 380/400 415/440 1000 115/120 200/208 230/240 265/277 460/480 1000 0.27 0.94 0.78 1.17 4.55 4.77 6.38 9.14 14.5 18.4 18.9 28.1 31.1 57.2 67.9 72.6 86.9 95.1 0.04 0.13 0.11 0.16 0.59 0.64 0.86 1.15 1.87 2.38 3.44 7.05 8.21 9.21 10.3 20.3 28.9 48.9 68.5 GLX1-FF024 GLX1-FF042 GLX1-FF040 GLX1-FF048 GLX1-FF092 GLX1-FF095 GLX1-FF110 GLX1-FF127 GLX1-FF162 GLX1-FF184 GLX1-FF187 GLX1-FF220 GLX1-FF240 GLX1-FF316 GLX1-FF340 GLX1-FF360 GLX1-FF380 GLX1-FF415 GLX1-FF500 GLX1-FF550 GLX1-FF660 GLX1-FF850 GLX1-FF1000 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430 0.430
contactors GLC1-F185 GLC1-F225
Specifications
Average consumption inrush sealed 0.34. 2400. Operating cycles/hour 220/230 380/400 415/440 1000 115/120 200/208 230/240 265/277 460/480 1000 0.18 0.57 0.47 0.71 2.74 2.87 4.18 5.35 11.1 11.4 16.5 20.1 40.8 43.5 51.3 62.3 82.7 0.03 0.09 0.08 0.12 0.44 0.49 0.65 0.86 1.41 1.87 2.59 3.09 5.32 6.94 7.75 9.06 12.8 15.3 21.8 36.6 51.6 GLX1-FG024 GLX1-FG042 GLX1-FG040 GLX1-FG048 GLX1-FG092 GLX1-FG095 GLX1-FG110 GLX1-FG127 GLX1-FG162 GLX1-FG184 GLX1-FG187 GLX1-FG220 GLX1-FG240 GLX1-FG316 GLX1-FG340 GLX1-FG360 GLX1-FG380 GLX1-FG415 GLX1-FG500 GLX1-FG550 GLX1-FG660 GLX1-FG850 GLX1-FG1000 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550 0.550
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors
sealed consumption. Operate networks with harmonic numbers Contactors type GLC1-F Coils GLC1-F265 F500, a.c. supply 40/400 References
Control circuit voltage 50Hz 60Hz
Average resistance
Inductance colsed circuit
Voltage code
Reference
Weight (kg)
contactors GLC1-F265 GLC1-F330
Specifications
Average consumption cos= inrush sealed 2400. Operating cycles/hour 110/115 120/127 200/208 220/230 380/415 480/500 600/660 1000 2.96 18.7 22.9 57.8 71.6 71.6 114.3 1218 1285 1621 1621 2425 5075 7990 GLX1-FH0482 GLX1-FH1102 GLX1-FH1272 GLX1-FH2002 GLX1-FH2202 GLX1-FH2402 GLX1-FH2772 GLX1-FH3802 GLX1-FH5002 GLX1-FH6002 GLX1-FH10002 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750
contactor GLC1-F400
Specifications
Average consumption cos= inrush 1000 1150 sealed Operating cycles/hour 2400. 110/120 200/208 220/230 230/240 265/277 380/400 415/480 550/600 1000 12.8 47.5 29.5 1030 1320 1700 3310 4070 4980 6310 0.18 1.35 1.75 15.8 19.4 25.5 27.4 84.6 GLX1-FJ048 GLX1-FJ110 GLX1-FJ127 GLX1-FJ200 GLX1-FJ220 GLX1-FJ240 GLX1-FJ280 GLX1-FJ380 GLX1-FJ415 GLX1-FJ500 GLX1-FJ600 GLX1-FJ1000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000
contactor GLC1-F500
Specifications
Average consumption cos= inrush 1050 1150 sealed 2400. Operating cycles/hour 110/120 200/208 220/230 230/240 265/277 380/400 415/480 550/600 1000 9.55 11.5 35.5 44.5 56.5 33.5 1160 1490 2980 3730 4590 5660 0.19 1.25 3.75 4.55 5.75 14.7 18.4 22.8 23.9 GLX1-FK048 GLX1-FK110 GLX1-FK127 GLX1-FK200 GLX1-FK220 GLX1-FK240 GLX1-FK280 GLX1-FK380 GLX1-FK415 GLX1-FK500 GLX1-FK600 GLX1-FK1000 1.150 1.150 1.150 1.150 1.150 1.150 1.150 1.150 1.150 1.150 1.150 1.150
Please consult your Regional customer centre.
Greegoo Electric 11.2007
http://www.greegoo.com
1-10
Motor Control Device
Magnetic contactors
sealed consumption. Operate networks with harmonic numbers
Contactors type GLC1-F Coils GLC1-F630 F780, a.c. supply References
contactor GLC1-F630
Specifications
Average consumption cos= inrush 1500 1730 sealed Operating cycles/hour 1200.
Control circuit voltage
110/120 200/208 220/240 265/277 380/400 415/480 550/600 1000
Average resistance 10%( Inrush Sealed
6.45 20.5 25.5 17.1 2360 2960 3660 4560
Inductance colsed circuit
0.09 1.85 1.05 2.65 3.35 10.5 16.5 19.5 56.2
Voltage code
Reference
Weight (kg)
1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500
GLX1-FL048 GLX1-FL110 GLX1-FL127 GLX1-FL200 GLX1-FL220 GLX1-FL260 GLX1-FL380 GLX1-FL415 GLX1-FL500 GLX1-FL600 GLX1-FL1000
contactor GLC1-F780
Specifications
Average consumption inrush 1900 2300 sealed Operating cycles/hour 600.
Control circuit voltage
110/120 200/208 220/240 265/277 415/480
Average resistance 10%( Inrush Sealed
4.95(2) 6.1(2) 15.5(2) 19.5(2) 29.8(2) 60.9(2) 74.3(2) 92(2) 230(2) 280(2) 750(2) 920(2) 1330(2) 2780(2) 3340(2) 4180(2)
Inductance colsed circuit
0.21 0.26 0.66 0.82 1.25
Voltage code
Reference
Weight (kg)
3.000 3.000 3.000 3.000 3.000 3.000 3.000 3.000
GLX1-FX110(1) GLX1-FX127(1) GLX1-FX200(1) GLX1-FX220(1) GLX1-FX280(1) GLX1-FX380(1) GLX1-FX415(1) GLX1-FX500(1)
Reference identical coils, connected series. Value coils series.
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors
1-11
sealed consumption. Contactors type GLC1-F Coils GLC1-F115 F400, d.c. supply References
Control circuit voltage
Average resistance 10%( Inrush Sealed
Inductance colsed circuit
Voltage code
Reference
Weight (kg)
contactors GLC1-F115 GLC1-F150
Specifications
Average consumption inrush sealed 3.94 4.83 220/230 440/460 1.12 4.52 21.7 26.8 2940 3560 42.7 4000 GLX4-FF024 GLX4-FF048 GLX4-FF110 GLX4-FF125 GLX4-FF220 GLX4-FF250 GLX4-FF440 0.430 0.430 0.430 0.430 0.430 0.430 0.430
contactors GLC1-F185 GLC1-F225
Specifications
Average consumption inrush sealed 4.13 5.07 220/230 440/460 0.79 14.9 57.7 2810 3320 14.9 55.3 1140 4210 GLX4-FG024 GLX4-FG048 GLX4-FG110 GLX4-FG125 GLX4-FG220 GLX4-FG250 GLX4-FG440 0.550 0.550 0.550 0.550 0.550 0.550 0.550
contactors GLC1-F265 GLC1-F330
Specifications
Average consumption inrush sealed 3.68 4.53 220/230 440/460 3.49 16.8 20.8 65.7 3180 3840 26.3 92.9 1590 1910 7570 GLX4-FH024 GLX4-FH048 GLX4-FH110 GLX4-FH125 GLX4-FH220 GLX4-FH250 GLX4-FH440 0.740 0.740 0.740 0.740 0.740 0.740 0.740
contactor GLC1-F400
Specifications
Average consumption inrush 1140 sealed 12.7 15.8 2660 3130 8820 1200 4435 GLX4-FJ048 GLX4-FJ110 GLX4-FJ125 GLX4-FJ220 GLX4-FJ250 GLX4-FJ440 0.970 0.970 0.970 0.970 0.970 0.970
Greegoo Electric 11.2007
http://www.greegoo.com
1-12
Motor Control Device
Magnetic contactors
sealed consumption.
Contactors type GLC1-F Coils GLC1-F500 F780, d.c. supply References
contactor GLC1-F500
Specifications
Average consumption inrush 1220 sealed
Control circuit voltage
Average resistance 10%( Inrush
2.35 11.5
Sealed
2450 2930 8150 9650
Inductance colsed circuit
1080 1350 5270
Voltage code
Reference
Weight (kg)
1.080 1.080 1.080 1.080 1.080 1.080
GLX4-FK048 GLX4-FK110 GLX4-FK125 GLX4-FK220 GLX4-FK250 GLX4-FK440
contactor GLC1-F630
Specifications
Average consumption inrush 1420 1920 sealed 72.5
Control circuit voltage
Average resistance 10%( Inrush
Sealed
1680 2110 5160 6080
Inductance colsed circuit
40.5 2910
Voltage code
Reference
Weight (kg)
1.450 1.450 1.450 1.450 1.450 1.450
GLX4-FL048 GLX4-FL110 GLX4-FL125 GLX4-FL220 GLX4-FL250 GLX4-FL440
contactor GLC1-F780
Specifications
Average consumption inrush 1960 2420 sealed
Control circuit voltage
Average resistance 10%( Inrush Sealed
6.1(2) 7.7(2) 24.6(2) 29.8(2) 92(2) 280(2) 410(2) 1100(2) 1330(2) 4180(2)
Inductance colsed circuit
0.26 0.33 1.25
Voltage code
Reference
Weight (kg)
3.000 3.000 3.000 3.000 3.000
GLX4-FX110(1) GLX4-FX125(1) GLX4-FX220(1) GLX4-FX250(1) GLX4-FX440(1)
Reference identical coils, connected series. Value coils series.
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors GLC1-D series magnetic contactor 115A-620A
Standard power ratings 3-phase motors 50/60 category AC-3 220V 240V (kW)
1-13
380V 400V (kW)
400V (kW)
500V (kW)
600V 690V (kW)
1000V (kW)
Rated operational current 440V
Thermal current Ithe
Reference
1000 1000
GLC1-D-1153 GLC1-D-1503 GLC1-D-1703 GLC1-D-2053 GLC1-D-2054 GLC1-D-2453 GLC1-D-2454 GLC1-D-3003 GLC1-D-3004 GLC1-D-4103 GLC1-D-4104 GLC1-D-4753 GLC1-D-4754 GLC1-D-6203 GLC1-D-6204
GLC2-D series reversing magnetic contactor 115A-620A
Standard power ratings 3-phase motors 50/60 category AC-3 220V 240V (kW)
380V 400V (kW)
400V (kW)
500V (kW)
600V 690V (kW)
1000V (kW)
Rated operational current 440V
Thermal current Ithe
Reference
1000 1000
GLC2-D-115 GLC2-D-150 GLC2-D-170 GLC2-D-2053 GLC2-D-2054 GLC2-D-2453 GLC2-D-2454 GLC2-D-3003 GLC2-D-3004 GLC2-D-4103 GLC2-D-4104 GLC2-D-4753 GLC2-D-4754 GLC2-D-6203 GLC2-D-6204
GLC3-D series star delta starter
Standard power ratings 3-phase motors 50/60 category AC-3 220V (kW)
220V (hp)
380V (kW)
380V (hp)
415V 440V (kW)
415V 440V (hp)
Rated operational current AC-3 440V
Rated insulation voltage
1000 1000 1000 1000 1000 1000
Thermal current Ithe
Reference
1000
GLC3-D245 GLC3-D300 GLC3-D410 GLC3-D475 GLC3-D620
Greegoo Electric 11.2007
http://www.greegoo.com
GLC3-D205
1-14
Motor Control Device
Magnetic contactors GLC1-D series magnetic contactors pole
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
18.5 18.5 18.5 18.5
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLC1-D0911 GLC1-D1211 GLC1-D1811 GLC1-D2511 GLC1-D3211 GLC1-D4011 GLC1-D5011 GLC1-D6511 GLC1-D8011 GLC1-D9511
GLP1-D series magnetic contactors pole
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
18.5 18.5 18.5 18.5
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLP1-D0911 GLP1-D1211 GLP1-D1811 GLP1-D2511 GLP1-D3211 GLP1-D4011 GLP1-D5011 GLP1-D6511 GLP1-D8011 GLP1-D9511
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors GLC1-D series contactors pole
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
18.5 18.5 18.5 18.5
1-15
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLC1-D09004 GLC1-D09008 GLC1-D12004 GLC1-D12008 GLC1-D25004 GLC1-D25008 GLC1-D40004 GLC1-D40008 GLC1-D50004 GLC1-D50008 GLC1-D65004 GLC1-D65008 GLC1-D80004 GLC1-D80008 GLC1-D95004 GLC1-D95008
GLP1-D series contactors pole
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
18.5 18.5 18.5 18.5 18.5 18.5
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLP1-D09004 GLP1-D09008 GLP1-D12004 GLP1-D12008 GLP1-D25004 GLP1-D25008 GLP1-D40004 GLP1-D40008 GLP1-D50004 GLP1-D50008 GLP1-D65004 GLP1-D65008 GLP1-D80004 GLP1-D80008 GLP1-D95004 GLP1-D95008
http://www.greegoo.com
Greegoo Electric 11.2007
1-16
Motor Control Device
Magnetic contactors GLC1-DN series magnetic contactors pole
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
18.5 18.5 18.5 18.5
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLC1-DN0911 GLC1-DN1211 GLC1-DN1811 GLC1-DN2511 GLC1-DN3211 GLC1-DN4011 GLC1-DN5011 GLC1-DN6511 GLC1-DN8011 GLC1-DN9511
ELC1-D series magnetic contactors pole
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
18.5 18.5 18.5 18.5
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
ELC1-D0911 ELC1-D1211 ELC1-D1811 ELC1-D2511 ELC1-D3211 ELC1-D4011 ELC1-D5011 ELC1-D6511 ELC1-D8011 ELC1-D9511
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors Reversing magnetic contactors GLC2-D
3-pole reversing contactors horizontally mounted
a.c. control circuit
1-17
Basic reference. Complete with code indicating control circuit voltage Fixing, cabing Weight
Standard power ratings 3-phase motors 50/60 category AC-3 (kW) 220V 230V
18.5
Rated operational current 380V 415V 440V 500V 660V AC-3 400V 690V 440V
18.5 18.5 18.5
Instantaneous auxiliary contacts contactor
GLC2-D0910 GLC2-D1201 GLC2-D1801 GLC2-D2501 GLC2-D3201 GLC2-D4011 GLC2-D5011 GLC2-D6511 GLC2-D8001 GLC2-D9511
0.700 0.700 0.750 1.100 1.200 2.400 2.400 2.400 3.200 3.200
98(up 400V)
Reversing magnetic contactors GLP2-D
Standard power ratings 3-phase motors 50/60 category AC-3 (kW) 220V 230V
Rated operational current 380V 415V 440V 500V 660V AC-3 400V 690V 440V
18.5 18.5
Instantaneous auxiliary contacts contactor
Basic reference. Complete with code indicating control circuit voltage Fixing, cabing
Weight
GLP2-D0901 GLP2-D1201 GLP2-D1801 GLP2-D2501 GLP2-D3201
1.200 1.200 1.270 1.750 1.850
GLC3-D star delta starter
Standard power ratings squirrel cage Auxi liary contacts available motors mains voltage-delta connection each contactor line deita star 220V (kW)
18.5
380V (kW)
18.5
415V (kW)
440V (kW)
Star-delta mechanical interlock
Reference
Without Without Without Without Without Without Without Without Without Without
QJX2-09 QJX2-12 QJX2-18 QJX2-25 QJX2-32 QJX2-40
http://www.greegoo.com
QJX2-50 QJX2-65 QJX2-80 QJX2-95
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors range contactors
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
Control circuit: a.c.
1-18
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLC1-K0610 GLC1-K0601 GLC1-K0910 GLC1-K0901 GLC1-K1210 GLC1-K1201
Reversing contactors motor control Control circuit: a.c. GLC2-K0610 GLC2-K0601 GLC2-K0910 GLC2-K0901 GLC2-K1210 GLC2-K1201
Control circuit: d.c. GLP1-K0610 GLP1-K0601 GLP1-K0910 GLP1-K0901 GLP1-K1210 GLP1-K1201
Reversing contactors motor control Control circuit: d.c. GLP2-K0610 GLP2-K0601 GLP2-K0910 GLP2-K0901 GLP2-K1210 GLP2-K1201
Greegoo Electric 11.2007
http://www.greegoo.com
1-19
Motor Control Device
Magnetic contactors range control relays
Number contacts
Composition
Reference
Control circuit: a.c. Control circuit: d.c. GLA3-K40Z GLA3-K31Z GLA3-K22Z GCA2-K40 GCA2-K31 GCA2-K22
range auxiliary contact blocks GLA1-KN11 GLA1-KN20 GLA1-KN02 GLA1-KN22 GLA1-KN31 GLA1-KN13 GLA1-KN40 GLA1-KN04
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors range contactors
Standard power ratings 3-phase motors 50/60 category AC-3 220V 380V 415V 440V 500V 660V 230V 400V (kW) (kW) (kW) 690V (kW) (kW) (kW)
Control circuit: a.c.
1-20
Rated operational current AC-3 440V
Rated operational current AC-1 440V
Reference Rated Instantaneous noncon- auxiliary contacts dutive voltage
GLC1-EC03 GLC1-EC09 GLC1-EE03 GLC1-EE09
Control circuit: d.c. GLP1- EC03 GLP1- EC09 GLP1- EE03 GLP1- EE09
Reversing contactors motor control Control circuit: a.c. GLC2- EC03 GLC2- EC09 GLC2- EE03 GLC2 EE09
Greegoo Electric 11.2007
http://www.greegoo.com
1-21
Motor Control Device
Magnetic contactors range control relays
Number contacts
Composition
Reference
Control circuit: a.c. Control circuit: d.c. CA2-E40Z CA2-E31Z CA2-E22Z CA2-E40 CA2-E31 CA2-E22
range auxiliary contact blocks GLA1-EN11 GLA1-EN20 GLA1-EN02
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors Control circuit: a.c. d.c.
Number contacts Composition Reference
1-22
Control circuit: a.c. Control circuit: d.c. GCA3-40Z GCA3-31Z GCA3-22Z GCA2-40 GCA2-31 GCA2-22
Auxiliary contact blocks GLA8-11 GLA8-20
Auxiliary contact blocks GLA1-11 GLA1-20 GLA1-02 GLA1-22 GLA1-31 GLA1-40 GLA1-04 GLA1-04
Time delay contact blocks GLA2-20 GLA2-22 GLA2-24 GLA2-30 GLA2-32 GLA2-34
Greegoo Electric 11.2007
http://www.greegoo.com
1-23
Motor Control Device
Magnetic contactors CJ19 series contactors capacitor switching
Contactor selection operating power 50/60Hz 0<40 220V 240V (kVAR)
400V 440V (kVAR)
12.5 12.5 12.5 16.7 16.7 16.7 33.3 33.3
220V 240V (kVAR)
400V 440V (kVAR)
13.3 13.3 13.3 16.7 16.7 16.7
Thermal current Ithe
Instantaneous auxi liary contacts
Reference
CJ19-2511 CJ19-2520 CJ19-2502 CJ19-3211 CJ19-3220 CJ19-3202 CJ19-4311 CJ19-4320 CJ19-4302 CJ19-5012 CJ19-5021 CJ19-6021 CJ19-6012 CJ19-8021 CJ19-8012 CJ19-12521 CJ19-12512
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors E3RT series contactors
Application
1-24
E3RT Series contactors suitable frequency 50/50Hz, rated insulation voltage 690-1000V, rated operational current 7A-95A rated operational voltage 380V under utilization category AC-3. They mainly used making breaking electric circuits long distance frequent starting stopping reversing control motors. They comply with IEC947, VDE0660, 14048.
Technical parameter
Standard power ratings 3-phase motors 50/60 category AC-3 230V (kW)
18.5
400V (kW)
18.5
500V (kW)
18.5
690V (kW)
18.5
1000V (kW)
Rated operational current 440V
Reference Rated operational current AC-1 440V
E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10 E3RT-10
Dimension
E3RT-12 E3RT-25
E3RT-50
E3RT-95
Greegoo Electric 11.2007
http://www.greegoo.com
1-25
Motor Control Device
Magnetic contactors E3TF series contactors
Application
E3TF contactor applies supply 50/60Hz, rated voltage 660V. use, under voltage 380V, rated current 630A. E3TF overload relay form motor starter protect motors against overload phase failure. product test according IEC60947-4. contactor features double breaking contacts. distinguish chambers used quench contactors above. contactors below mounted rail screw, bigger ones only mounted screw.
Technical parameter
Controllable power motor (kW) AC-3 380V
18.5
660V
AC-4 380V
Rated operation current 380V
660V
15.5 20.8 24.3 29.5 46.9
660V
12.5 16.5
Thermal Type current Ithe auxiliary contact
1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO 2NC+2NO, 4NC+4NO
Reference
E3TF-40 E3TF-41 E3TF-42 E3TF-43 E3TF-44 E3TF-45 E3TF-46 E3TF-47 E3TF-48 E3TF-49 E3TF-50 E3TF-51 E3TF-52 E3TF-53 E3TF-54 E3TF-55 E3TF-56 E3TF-68
E3TB series contactors
Application
contactor suitable application circuits rated voltage 660V 50/60Hz, rated current 630A, making breaking, frequent starting controlling motor. After combined with mechanical interlocking device, becomes CJX1-B convertible contactor controlling, starting breaking reversing motor. products comply with IEC60947-4.
Technical parameter
Controllable power motor (kW) 380V
http://www.greegoo.com
Rated operating current 380V
660V
660V
13.5 13.5
Thermal current Ithe
Type auxiliary contact
Reference
1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 1NO+1NC, 2NO+2NC 2NC+2NO
E3TB-40 E3TB-41 E3TB-42 E3TB-43 E3TB-44
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors E3TD series contactors
Application
1-26
contactor suitable using circuits rated voltage 660V 50/60Hz, current 300A, convertibley controlling motor. mechanical interlocking device ensures contact changeover convertible contactors.
Technical parameter
Controllable power motor (kW) AC-3 380V
18.5
660V
AC-4 380V
Rated operation current 660V
15.5 20.8 24.3 29.5 46.9
Thermal current Ithe
Reference
380V
660V
12.5 16.5 E3TD-40 E3TD-41 E3TD-42 E3TD-43 E3TD-44 E3TD-45 E3TD-46 E3TD-47 E3TD-48 E3TD-49 E3TD-50 E3TD-51 E3TD-52 E3TD-53 E3TD-54 E3TD-55
Greegoo Electric 11.2007
http://www.greegoo.com
1-29
Motor Control Device
Magnetic contactors
4-pole contactors type LC1-D a.c. coils References
Control circuit voltage
Average resistance.
Inductance closed circuit
Reference Average resistance.
Inductance closed circuit
Reference
Weight (kg)
contactors LC1-D09, D12,
Specifications
Average consumption inrush (cos= 0.75) sealed (cos= 0.3) Operating range 50Hz LX1-D2B5 LX1-D2C5 LX1-D2D5 LX1-D2E5 LX1-D2F5 LX1-D2G5 LX1-D2M5 LX1-D2P5 LX1-D2U5 LX1-D2W5 LX1-D2Q5 LX1-D2V5 LX1-D2N5 LX1-D2R5 LX1-D2S5 LX1-D2Y5 60Hz 5.45 22.09 116.6 139.2 417.8 490.2 587.4 781.5 1486 1826 1892 2304 3432 3678 0.25 1.02 16.6 18.5 LX1-D2B6 LX1-D2E6 LX1-D2F6 LX1-D2G6 LX1-D2L6 LX1-D2M6 LX1-D2U6 LX1-D2W6 LX1-D2Q6 LX1-D2N6 LX1-D2R6 LX1-D2T6 LX1-D2S6 LX1-D2X6 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070
220/230 380/400
6.82 12.26 21.32 28.05 148.2 192.5 613.3 649.7 726.6 1848 2069 2219 2549 3285 5631
0.48 0.93 1.22
Specifications
Average consumption inrush (cos= 0.75) 50/60 sealed (cos= 0.3) 50/60 0.85 Operating range 50/60Hz LX1-D2B7 LX1-D2D7 LX1-D2E7 LX1-D2F7 LX1-D2G7 LX1-D2M7 LX1-D2P7 LX1-D2U7 LX1-D2Q7 LX1-D2V7 LX1-D2N7 LX1-D2R7
220/230 230/240 380/400
6.19 19.15 1580 1810 1938 2242
0.26 0.77
0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070
http://www.greegoo.com
last digits reference represent voltage code. Voltage special coils fitted contactors with serial timer modules, with supply. This coil used This coil used 230/240 only
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors
1-30
4-pole contactors type LC1-D a.c. coils References
Control circuit voltage
Average resistance.
Inductance closed circuit
Reference Average resistance.
Inductance closed circuit
Reference
Weight (kg)
contactors LC1-D25, (except LC1-D2500)
Specifications
Average consumption inrush (cos= 0.75) sealed (cos= 0.3) 50Hz Operating range 50Hz LX1-D4Z5 LX1-D4B5 LX1-D4C5 LX1-D4D5 LX1-D4E5 LX1-D4F5 LX1-D4G5 LX1-D4M5 LX1-D4P5 LX1-D4U5 LX1-D4W5 LX1-D4Q5 LX1-D4V5 LX1-D4N5 LX1-D4R5 LX1-D4S5 LX1-D4Y5 60Hz 14.5 1010 1315 1605 2360 2480 0.14 0.18 0.72 LX1-D4Z6 LX1-D4B6 LX1-D4E6 LX1-D4F6 LX1-D4G6 LX1-D4L6 LX1-D4M6 LX1-D4U6 LX1-D4W6 LX1-D4Q6 LX1-D4R6 LX1-D4T6 LX1-D4S6 LX1-D4X6 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070
220/230 380/400
14.4 18.6 1306 1389 1595 1710 2168 3984
0.23 0.25 0.45 0.78
Specifications
Average consumption inrush (cos= 0.75) 50/60 sealed (cos= 0.3) 50/60 0.85 Operating range 50/60Hz LX1-D4Z7 LX1-D4B7 LX1-D4D7 LX1-D4E7 LX1-D4F7 LX1-D4G7 LX1-D4M7 LX1-D4P7 LX1-D4U7 LX1-D4Q7 LX1-D4V7 LX1-D4N7 LX1-D4R7
220/230 230/240 380/400
13.5 1186 1200 1383 1478
0.18 0.23 0.69 0.92
0.085 0.085 0.085 0.085 0.085 0.085 0.085 0.085 0.085 0.085 0.085
http://www.greegoo.com
0.085 0.085
last digits reference represent voltage code. Voltage special coils fitted contactors with serial timer modules, with supply. This coil used This coil used 230/240 only
Greegoo Electric 11.2007
1-31
Motor Control Device
Magnetic contactors
4-pole contactors type LC1-D a.c. coils References
Control circuit voltage
Average resistance.
Inductance closed circuit
Reference Average resistance.
Inductance closed circuit
Reference
Weight (kg)
contactors LC1-D40,D50,D65,D80,D95
Specifications
Average consumption inrush (cos= 0.75) sealed (cos= 0.3) 50Hz 0.85 Operating range 50Hz LX1-D6B5 LX1-D6C5 LX1-D6D5 LX1-D6E5 LX1-D6F5 LX1-D6G5 LX1-D6M5 LX1-D6P5 LX1-D6U5 LX1-D6W5 LX1-D6Q5 LX1-D6V5 LX1-D6N5 LX1-D6R5 LX1-D6S5 LX1-D6Y5 60Hz 1.05 0.06 0.23 LX1-D6B6 LX1-D6E6 LX1-D6F6 LX1-D6G6 LX1-D6L6 LX1-D6M6 LX1-D6U6 LX1-D6W6 LX1-D6Q6 LX1-D6R6 LX1-D6T6 LX1-D6S6 LX1-D6X6 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280
220/230 380/400
1220
0.09 0.16 0.27 0.35
Specifications
Average consumption inrush (cos== 0.75) sealed (cos= 0.3) 50/60 0.85 Operating range 50/60Hz LX1-D6B7 LX1-D6D7 LX1-D6E7 LX1-D67 LX1-D6G7 LX1-D6M7 LX1-D6P7 LX1-D6U7 LX1-D6Q7 LX1-D6V7 LX1-D6N7 LX1-D6R7
220/230 230/240 380/400
http://www.greegoo.com
1.22
0.08 0.25 0.32
0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.280
last digits reference represent voltage code. apply multiplying factor mechanical life contactor. This coil used This coil used 220/240 only apply multiplying factor mechanical life contactor.
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors contactors LP1-D09, D12,
Specifications
Average consumption Operating range
1-32
4-pole contactors type LP1-D d.c. coils References
Average resistance.
45.4 149.7 1411 1781 5235 6433
Control circuit voltage
21(1)
Inductance closed circuit
0.79 2.16 11.9 61.8 77.8 1393
Voltage code
Reference
Weight (kg)
LX4-D2JD LX4-D2ZD LX4-D2BD LX4-D2CD LX4-D2ED LX4-D2ND LX4-D2SD LX4-D2FD LX4-D2GD LX4-D2MD LX4-D2UD LX4-D2RD LX4-D2XD
0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175
contactors LP1-D25,
Specifications
Average consumption Operating range
Control circuit voltage
21(1)
Average resistance.
131.3 36.4 120.3 1122 1431 4461 6044 17450 33610
Inductance closed circuit
0.73 2.11 2.92 7.17 11.3 17.8 27.5 63.6 1706
Voltage code
Reference
Weight (kg)
LX4-D4JD LX4-D4ZD LX4-D4BD LX4-D4CD LX4-D4ED LX4-D4ND LX4-D4SD LX4-D4FD LX4-D4GD LX4-D4MD LX4-D4UD LX4-D4RD LX4-D4XD
0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.265
Voltage special coils fitted contactors with serial timer modules, with supply.
Greegoo Electric 11.2007
http://www.greegoo.com
1-33
Motor Control Device
Magnetic contactors
4-pole contactors type LP1-D d.c. coils References
contactors LP1-D40, D50,
Specifications
Average consumption Operating range 0.85
Control circuit voltage
Average resistance.
26.8 2255 2940 9080
Inductance closed circuit
0.44 1.69 3.55 6.86 10.9 14.7 35.28 45.2 1085
Voltage code
Reference
Weight (kg)
LX4-D6JD LX4-D6BD LX4-D6CD LX4-D6ED LX4-D6ND LX4-D6SD LX4-D6FD LX4-D6GD LX4-D6MD LX4-D6UD LX4-D6RD LX4-D6XD
0.415 0.415 0.415 0.415 0.415 0.415 0.415 0.415 0.415 0.415 0.415 0.415
contactors LP1-D80
Specifications
Average consumption Operating range 0.85
Control circuit voltage
Average resistance.
2215 2850 9195
Inductance closed circuit
0.46 1.89 11.9 16.1 39.5 50.3 1220
Voltage code
Reference
Weight (kg)
LX4-D7JD LX4-D7BD LX4-D7CD LX4-D7ED LX4-D7ND LX4-D7SD LX4-D7FD LX4-D7GD LX4-D7MD LX4-D7UD LX4-D7RD LX4-D7XD
0.680 0.680 0.680 0.680 0.680 0.680 0.680 0.680 0.680 0.680 0.680 0.680
http://www.greegoo.com
Greegoo Electric 11.2007
Motor Control Device
Magnetic contactors
Control circuit voltage Average resistance. Inductance closed circuit Voltage code Reference Weight (kg)
1-34
4-pole contactors type LP1-D Wide range d.c. coils specific applications References
contactors LP1-D09, D12,
Specifications
Average consumption Operating range 1.25 Coils with treatment standard. 15.6 58.7 122.6 1105 4593 0.71 2.49 21.4 44.4 LX4-D2JW LX4-D2BW LX4-D2CW LX4-D2EW LX4-D2SW LX4-D2FW LX4-D2MW 0.175 0.175 0.175 0.175 0.175 0.175 0.175
contactors LP1-D25,
Specifications
Average consumption Operating range 1.25 Coils with treatment standard. 12.3 49.2 100.7 3953 0.68 2.71 5.57 10.8 22.3 LX4-D4JW LX4-D4BW LX4-D4CW LX4-D4EW LX4-D4SW LX4-D4FW LX4-D4MW 0.265 0.265 0.265 0.265 0.265 0.265 0.265
contactors LP1-D40, D50,
Specifications
Average consumption Operating range 0.75 Coils with treatment standard. 2120 0.45 14.2 38.3 LX4-D6JW LX4-D6BW LX4-D6CW LX4-D6EW LX4-D6SW LX4-D6FW LX4-D6MW 0.415 0.415 0.415 0.415 0.415 0.415 0.415
contactors LP1-D80
Specifications
Average consumption Operating range 0.75.1.2 Coils with treatment standard. 23.5 51.9 94.2 1922 0.49 1.75 4.18 15.7 LX4-D7JW LX4-D7BW LX4-D7CW LX4-D7EW LX4-D7SW LX4-D7FW LX4-D7MW 0.680
http://www.greegoo.com
0.680 0.680 0.680 0.680 0.680 0.680
Greegoo Electric 11.2007
Motor Control
Contactor CJX7-9~110 Series Contactor
Application
CJX7-9~110 contactor (hereafter refer contactor) mainly used power system with 50Hz 60Hz), therated working voltage 660V, under appplication category AC-3, when rated working voltage 380V, rated operating current 110A electrical, long-distance range making breaking electric circuit, combines electromagnetism starter with suitable thermal overload relay electronic protector protect against possible overload electric circuit during operation(running).
Type meaning
contact Design code basic specification code indicated with rated working voltage 380V rated operating current numerical value under AC-3 application category main contact pair indicatedwith figures, ones placeexpressed contact Pair; tens digit expressed contact pair; auxiliary contact pair indicated with figures, ones placeexpressed contact pair, tens digit expressed contact pair;
CJX7-9(A)
Main Structure Working Principle
structure contactor positive mounted straight action type double-break dots, cover body made proof plastic, CJX7-9~16 uses auto extinguishing arc, CJX7-26~110 ''u'' shape extinguishing piece body form seal explosion chamber. extinguishing good, over distance zero. contact made anti-fusion welding bears silver base alloy material wear electricity with good electric conductivity, long life, does have pollution environment. ferrite core has''E'' shape structure, small volume. There kinds coil wiring ways user choice, terminals identical product; other terminals product beginnings ends, wiring flexible convenient. base made glass fiber reinforced plastics with high intensity, good dielectric properties. installation bolt, also guide rail installment. disassemble assemble very convenient rapid. electric conduction part does appear externally, security performance good.
CJX7-26(A)
working principle contactor: control power source making(breaking) contactor pullin coil, magnetism system produces(vanishes) electromagnetism suction drive moving part making (breaking) circuit through then, realize goal control.
Normal Working Condition Mounting condition
installation site elevation does surpass 2000m; Ambient temperature should over +40, also over within 24h, lower limit ambient temperature relative humidity installation site should over when maximum temperature +40; higher relative humidity allowed under lower temperature, foir example, must take measures product occuring because change temperature. installation site pollution chass contactor mounted vertically horizontally. vertically mounts, gradient between mounter surface perpendicular plane bigger than ±30%; (See Fig1).
CJX7-30(A)
http://www.greegoo.com
Greegoo Electric 7.2007
Motor Control
Contactor
Technical parameter
allowable application category main circuit auxiliary circuit contactor it's code Table application category main circuit auxiliary circuit contactor it's code Application category code
AC-1 AC-2 AC-3 AC-4 AC-15 DC-13
Circuit
Main circuit
Example typical usage
Noninductive micro ineuductive load, resistance furnace starting breaking wire winding type asynchronous motor starting breaking during operation cage asynchronous motor starting, plug braking reverse revolution, spot moving cage asynchronous motor Control electromagnet load (>72VA) Control magnet load
Auxliary circuit
Contactor reated insulation voltage (Ui), rated working voltage (Ue), conventional free heat current (lth), rated operating current (le)and rated work rate Table
Type CJX7-9 CJX7-12 CJX7-16 CJX7-26 CJX7-30 CJX7-40 CJX7-50 CJX7-63 CJX7-75 CJX7-95 CJX7-110
Frame Rated insulation Convensional free AC-3 rated operating current Control max.power generator code voltage heat current 220V 380V 220V 380V 660V 18.5 18.5
making breaking capacity main contacts contactor Table Making I/Ie
Type
CJX7-9~110
U/Ue
1.05
Making breaking Ic/Ie Ur/Ue
1.05
There auxiliary contact modules contactor user choice, kind contact front-loading auxiliary contact module, other contact side-loading type auxiliary contact module. CJX7-9~40 contactor body have pair contact auxiliary contact. basic parameter auxiliary circuit Table
Application class AC-15 DC-13
Rated insulated power supply
Conventional free thermal current
Rated control capacity Connecting Breaking 3600VA 360VA
Rated operating current 220V 380V 1.65 0.95 0.15
contactors suitable eight hours working system, uninterrupted working system, interruption period working system short time working system, operating frequency sees Table load factor under interruption period working system 40%. Type
CJX7-9-40 CJX7-50-110 CJX7-9-40 CJX7-50-110 CJX7-9-40 CJX7-50-110 CJX7-9-40 CJX7-50-110
Application class
AC-1 AC-2 AC-3 AC-4
Frequency times/h 220V
1200 1200 1200
380V
1200 1200 1200
660V
Greegoo Electric 3.2007
http://www.greegoo.com
Motor Control
Contactor
contactor endures overload current capability: withstand overload current 380V under AC-3 application category, power-on time 10s. contactor with short-circuit protective device (SCPD), recommendate SCPD RT16 (NT) series fuse, combination situation Table Fuse model
RT16-160 RT16-160 RT16-160
Type
CJX7-9-30 CJX7-40-63 CJX7-75-110
Fuse body rated current
Working condition basic parameter control loop
Controls coils 50Hz, source voltage rated control 36V, 110V, 220V, 380V, other specifications consult with factory. Contactors reliably pullin within rated control supply voltage 85%~110% scope, release voltage higher than rated control supply voltage, also lowest released voltage lower than rated control supply voltage. withstand thermal class control coils Class consumed power Table apparent power Starting
126.8 126.8 169.6 457.8
Type
CJX7-9, CJX7-26 CJX7-30, CJX7-50, CJX7-95,
Work power Ppullin
15.7 15.7 17.2 38.5 12.2
Mounting
section scope connecting conductor contactor terminal Table Main circuit simple root Multi-strand
2x1-4 2x1.5-6 2x2.5-16 1x6-50, 2x6-25 1x6-70, 2x6-35 2x0.75-2.5 2x1-4 2x2.5-10 1x6-35, 2x6-16 1x6-70, 2x6-35
Type
CJX7-9, CJX7-26 CJX7-30, CJX7-50, CJX7-95,
Auxiliary circuit Control circuit simple root Multi-strand simple root Multi-strand
2x1-4 2x1-4 2x1-4 2x1-4 2x1-2.5 2x0.75-2.5 2x0.75-4 2x0.75-2.5 2x0.75-2.5 2x0.75-2.5 2x1-4 2x1-4 2x1-4 2x1-4 2x1-2.5 2x0.75-2.5 2x0.75-2.5 2x0.75-2.5 2x0.75-2.5 2x0.75-2.5
Correct install wiring Note that terminal symbole: Main circuit 1L1, 3L2, incoming terminal; 2T1, 4T2, outgoing terminal. incoming terminal auxiliary contact 43.the outgoing terminal auxiliary contact 44.the outgoing terminal auxiliary contact 41.the outgoing terminal auxiliary contact 42.the coil terminal Contactors Overall installation dimensions Figure Figure Figure Figure table
http://www.greegoo.com
CJX7-9, dimension
Greegoo Electric 7.2007
Motor Control
Contactor
CJX7-26, dimension
CJX7-50, dimension
CJX7-95, dimension Type CJX7-9, CJX7-26 CJX7-30, CJX7-50, CJX7-95,
12.5 12.5 12.5 12.5 12.5 93.5 108.5 120.5 135.2 Mounting mode Screw mounting TH35 rail mounting Screw mounting TH35 TH75 rail mounting Screw mounting TH75 rail mounting
http://www.greegoo.com
148.5 123.5
Greegoo Electric 3.2007
Motor Control
Contactor
Maintenange
contactor should maintained regularly, prompt eliminate dust contactor with vacuum cleaner. contactors sends noise when work, dust ferrite core pole face should eliminated, inspects whether short circuit ring cracks. surface contact contactor flat(see Fig.6) fired black result electric arc, which does affect future use, does need hammerdress clean, metal grain around coat have eliminate. contact should replaced stop using, contact surface seriously worn reveals basic material(Fig.7)
Points attention
Before connecting, check whether rated voltage frequency contact coil consistent with control supply voltage frequency. Before installing contactor, check whether technical parameter meet actual usage request(including control supply voltage, power control motor on). After connecting contactor, should carry loading operation. When connecting, bolt terminal non-terminal should screw tight same time. Wehn installing, please note cause bolt other matter falls contactor avoid moving part locking causing possible short circuit.
http://www.greegoo.com
Greegoo Electric 7.2007
Motor Control
Magnetic starter(Motor starter) GLE1-D series magnetic starter
Application
GLE1-D series magnetic starter mainly applied circuit 60Hz,Voltage 550V distance making breaking circuit frequently starting controlling motor, features small volume, light weight, power consumption, high efficiency, safe reliable performance etc.
Type meaning GLE1
GLE1-D
GREEGOO magnetic starter; Design code; Current code.
Specifications
Order Utilisation category AC-3 Standard power ratings 3-phase motors 50/60Hz 220/230V 380/400V 415V 440V 500V 18.5 18.5 18.5 18.5 18.5 18.5 Rated operational current AC-3 Enclosure typeprotection degree
GLE1-D(NEW)
GLE1-D094 GLE1-D093 GLE1-D124 GLE1-D123 GLE1-D188 GLE1-D185 GLE1-D258 GLE1-D255 GLE1-D325 GLE1-D405 GLE1-D505 GLE1-D655 GLE1-D805 GLE1-D955 GLE1-D094N GLE1-D093N GLE1-D124N GLE1-D123N GLE1-D188N GLE1-D185N GLE1-D258N GLE1-D255N GLE1-D325N GLE1-D405N GLE1-D505N GLE1-D655N GLE1-D805N GLE1-D905N
IP42 IP55 IP42 IP55 IP42 IP55 IP42 IP55 IP18.5 IP25 IP33 IP37 IP45 IP45 IP42 IP55 IP42 IP55 IP42 IP55 IP42 IP55 IP18.5 IP25 IP33 IP37 IP45 IP45
Greegoo Electric 5.2008
http://www.greegoo.com
Motor Control
Magnetic starter(Motor starter)
Outline mounting sizes
GLE1-D09~GLE1-D018
GLE1-D25~GLE1-D32
GLE1-D40~GLE1-D95
http://www.greegoo.com
Greegoo Electric 5.2008

Other recent searches


SN74LVTH16500 - SN74LVTH16500   SN74LVTH16500 Datasheet
SN54LVTH16500 - SN54LVTH16500   SN54LVTH16500 Datasheet
PB1000 - PB1000   PB1000 Datasheet
PB1010 - PB1010   PB1010 Datasheet
MPC823 - MPC823   MPC823 Datasheet
MELFSMA5817-5819 - MELFSMA5817-5819   MELFSMA5817-5819 Datasheet
EPJ4005-F2 - EPJ4005-F2   EPJ4005-F2 Datasheet
DS92LV16 - DS92LV16   DS92LV16 Datasheet
CLM2B-REW - CLM2B-REW   CLM2B-REW Datasheet
CLM2B-AEW - CLM2B-AEW   CLM2B-AEW Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheets.org.uk