Datasheets.org.uk - 100 Million Datasheets from 7500 Manufacturers. |
Selection guide pages 1/43 References uages 2/70 2'101 Dimensions
Top Searches for this datasheetContactors protection relays Selection guide pages 1/43 References uages 2/70 2'101 Dimensions pages 2/88 2-91 2/102 2/103 Schemes pages 2/92. 2'93 2"03 Contactors, types LC1-D LP1-D Control circuit: a.c. d.c. Characteristics Type LC1-D09 LC1-D12 LC1-D18 LC1-D25 LP1-D09 LP1-D12 LP1-D18 LP1-D25 Environment Rated insulation voltage (Ui) IEC/EN 60947-4-1, overvoltage cateqory degree pollution: 1000 1000 1000 1000 Conforming Rated impulse withstand voltage (Uimp) Conforming IEC/EN 60947-4-1 Conforming standards IEC/EN 60947-1. 60947-4-1, 63-110, 0660, 1038. Approvals ASE, CSA, DEMKO, NEMKO, SEMKO, Conforming SNCF, Sichere Trennunq recommendations Degree protection Conforming 0106 Power connections Protection against direct finqer contact Coil connections Protection aqainst direct finqer contact Protective treatment Conforming IEC/EN 60068 "TH" Ambient temperature around device Storage -60.+80 Operation -5.+55 Permissible 40.+ operation Maximum operating altitude Without derating 3000 Operatinq positions Without derating possible, relation normal vertical mounting plane Flame resistance Conforming Conforming 695-2-1 960" Shock resistance sine wave 11ms Contactor open Contactor closed Vibration resistance 5.300 Contactor open Contactor closed Pole characteristics Number poles Rated operational current (le) AC-3, AC-1. 8S55 Rated operational voltage (Uel Frequency limits operational current 25.400 25.400 25.400 25.400 Rated thermal current (Ith) Rated making capacity Conforming IEC/EN 60947-4-1 Rated breaking capacity Conforming IEC/EN 60947-4-1 Permissible short time rating from cold state, current flowing previous minutes, Short-circuit protection fuses Without thermal overload relay. fuse type type With thermal overload relay pages 1/128 1/129, ratings fuses corresponding associated thermal overload relay Average impedance pole Power dissipation pole above operational currents AC-3 0.20 0.36 1.25 AC-1 1.56 1.56 Protection provided cable c.s.a. indicated pages 2/62 2/63 cable connections. least favourable direction, without change contact state (coil supplied Ue). 2/56 Contactors protection relays LC1-D32 LCI-040 LC1-D50 LC1-D65 LC1-D80 LC1-D95 LC1-D115 LC1-D150 LP1-D32 LP1-D40 LP1-D65 LP1-D80 1000 1000 1000 1000 1000 1000 1000 1000 IEC/EN 60947-1. 60947-4-1. 63-110. 0660. 1038. ASE, DEMKO. NEMKO, SEMKO. CSA. Conforming Sichere Trennung recommendations Protection aqainst direct finger contact Protection against direct finger contact except LP1-D40.D80 "TH" -60.+ -5.+55 40.+70, operation 3000 possible, relation normal vertical mounting plane. 960" 1000 1000 1000 1000 1000 1000 1000 25.400 25.400 25.400 25.400 25.400 25.400 25.400 25.400 Conforming IEC/EN 60947-4-1 Conforming IEC/EN 60947-4-1 1100 1100 1400 1200 pages 27012/2 27012/3, ratings fuses corresponding associated thermal overload relay. 13.5 12.5 12.5 2/57 Contactors protection relays Selection guide paqes 1/12 1*43 References pages 2/70 Dimensions pages 2/88 2-91, 2/10. Schemes pages 2/92, 2';93 2/103 Contactors, type LC1-D Control circuit: a.c. Characteristics (continued) Type LC1-D09 LC1-D12 L.C1-D18 LC1-D25 Control circuit characteristics Rated control circuit voltage (Uc) 21.660 Control voltage limits coils Operational 0,8.1.1 Drop-out 0.3.0.6 50/60 coils Operational 0.85.1.1 Drop-out 0.3.0.6 Average consumption Inrush coil 0.75 0.75 0.75 0.75 50/60 coil Sealed coil 50/60 coll Inrush coil 0.75 0.75 0.75 0.75 50/60 coil Sealed coil 50/60 coil Heat dissipation 50/60 2.5.3.5 Operating time Closing 12.22 12.22 12.22 15.24 Opening 4.19 4.19 4.,19 5.19 Mechanical durability millions operating cycles coil 50/60 coil Maximum operating rate ambient temperature operating cycles hour 3600 3600 3600 3600 closing time measured from moment coil supply switched initial contact main poles. opening time measured from moment coil supply switched moment mains poles separate._ 2/58 Contactors protection relays LC1-D32 LC1-D40 LC1-D50 LC1-D65 LC1-D80 LC1-D95 LC1-D115 LC1-D150 21.660 24.660 24.500 0.8.1.1 0.85.1.1 0.85. 0.3.0.6 0.3.0.5 0.85.1.1 0.8.1.15 50/60 0.3.0.6 0.3.0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 2.5.3.5 6.10 6.10 6.10 6.10 6.10 15.24 20.26 20.26 20.26 20.35 20.50 25.35 5.19 8.12 8.12 8.12 6.20 6.20 6.20 20.55 3600 3600 3600 3600 3600 3600 2400 1200 ^|lWamecanlqw| 2/59 Contactors protection relays Selection guide pages 1/12 References pages 2/70 2/101 Dimensions pages 2;88 2'91. 2/102 2/103 Schemes panes 2/92 2/93 Contactors, type LP1-D Control circuit: d.c. Characteristics (continued) Type LP1-D09, D12, LP1-D25, LP1-D40, D50, LP1-D80 LC1-D115 LC1-D150 Control circuit characteristics Rated control circuit voltage (Uc) 12.440 12.440 24.440 Control voltage limits Operational Standard coil 0.8.1.1 0.85.1.1 0.7. Wide range coil 0.7.1.25 0.75. Drop-out 0.1.0.25 0.1.0.3 0.2.0.4 Average consumption Inrush Seated Operating time average Closing 40.48 52.64 85.110 95.130 Opening 6.14 8.14 20.35 20.35 20.35 Note: arcing time depends circuit switched poles. normal three-phase applications, arcing time normally less than load isolated from supply after time equal opening time arcinq time. Mechanical durability millions operating cycles Maximum operating rate ambient temperature operating cycles hour 3600 3600 3600 3600 1200 operating times depend type contactor electromagnet control mode. closing time measured from moment coil supply switched initial contact main poles. opening time measured from moment coil supply switched moment mains poles separate. 2/60 |"IM*mecanique Contactors protection relays Selection guide pages 1'12 1/43 Character,sties pages 2/56 2<69 Dimensions pages 2'88 2/91 Schemes pages 2'92 2/93 Contactors motor control, category AC-3 Control circuit: a.c. References 3-pole contactors connection cables with without cable ends Standard power ratings operat. auxiliary current contacts AC-3 440V 220V 380V 660V 230V 400V 415V 440V 500V 690V 1000V_ 3-phase motors 50/60 category AC-3 Rated Instantan. Ordering reference. Complete with code indicating control circuit voltage Fixing Weight 0.340 0.340 0.340 LC1-01800M LCI-PI 0.345 0.345 0.345 0.355 0.365 0.365 0.400 0.530 0.530 18.5 18.5 18.5 18.5 45_45 0.545 0.555 0.555 1.400 1.400 1.400 1.590 2.420 2.440 Note: 3-pole contactors without auxiliary contacts conform standard 50012. Auxiliary contact blocks modules: pages 2/78 2/85._ LC1-D09 D38: clip-on mounting "l_f rail AM1-DP screw fixing. LC1-D40 D95: clip-on mounting "L_r rail AM1-DE "L_r rail AM1-DL screw fixing. LC1-D115 D150: clip-on mounting "i_r rails AM1-DP screw fixing. Standard control circuit voltages. Volts LC1-D09.D115 06_- 50/60 Q7_V7 Other voltages from pages 2/104 2/107. LC1-D09.D150 (coils D115 D150 with integral suppression device fitted standard) 2/70 Other recent searchesY92B - Y92B Y92B Datasheet TMS320VC33 - TMS320VC33 TMS320VC33 Datasheet TMS320VC33-150 - TMS320VC33-150 TMS320VC33-150 Datasheet TMS320VC33-120 - TMS320VC33-120 TMS320VC33-120 Datasheet STBV42 - STBV42 STBV42 Datasheet SPX2967 - SPX2967 SPX2967 Datasheet PV37X200C01B00 - PV37X200C01B00 PV37X200C01B00 Datasheet 2CTD432194F1701 - 2CTD432194F1701 2CTD432194F1701 Datasheet
Privacy Policy | Disclaimer |